胸降主动脉近远端锥度的一致性:基于新型CT评估的量化研究
本研究基于281例连续个体的增强胸部CT,提出新参数HDP量化胸降主动脉近远端锥度。识别出3个拐点(HDP 15.01、36.63、77.74)将胸降主动脉分为4段,锥度在调整混杂因素后保持一致,各段直径每1%单位变化不同。
要点
- 胸降主动脉最大直径随HDP增加呈分段线性下降,存在3个拐点。
- 锥度在调整年龄、性别、身高、BMI、高血压、吸烟、高脂血症和糖尿病后仍一致。
- 各段每1%单位HDP对应的直径变化量不同,第二段下降最明显。
核心结论
- 在无主动脉疾病个体中,胸降主动脉最大直径随HDP增加而逐渐且一致地下降。
研究设计与样本
- 基于281例连续个体的增强胸部CT,使用3-mensio软件测量并计算HDP。
- 采用广义加性混合模型和广义估计方程分析HDP与最大直径的关联。
主要发现
- 识别出HDP为15.01、36.63和77.74三个拐点,将胸降主动脉分为4段。
- HDP<15.01段:每1%单位直径变化0.007 mm(-0.025, 0.010; P=0.414)。
- 15.01≤HDP<36.63段:每1%单位直径变化-0.151 mm(-0.158, -0.145; P<0.001)。
- 36.63<HDP≤77.74段:每1%单位直径变化-0.038 mm(-0.040, -0.036; P<0.001)。
- HDP>77.74段:每1%单位直径变化-0.026 mm(-0.049, -0.002; P=0.035)。
临床怎么用
- 可为胸主动脉腔内修复术远端锚定区支架尺寸选择提供量化参考。
- HDP分段及对应直径变化趋势有助于减少对操作者经验的依赖。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Successful endovascular repair of thoracic aorta for type B aortic dissection requires correct stent-graft sizing, particularly of distal landing zone which is mainly based on operator experience. The present study aimed to quantitatively define proximal-to-distal tapering of descending thoracic aortic diameter and its consistency. METHODS: The novel parameter HDP (Hundred times Distance accounts for Percentage)-measured as distance from the distal end of the left subclavian artery to each level along the aortic central line/length from the distal end of the left subclavian artery to the proximal end of the celiac artery along the aortic central line × 100-was calculated per 1% unit of descending thoracic aorta based on 3-mensio software-derived measurements from 281 consecutive individuals who had undergone enhanced chest computer tomography scanning. Association between HDP and maximal diameter of descending thoracic aorta was assessed by using the generalized additive mixed model with smoothing function and threshold saturation effect analyses with generalized estimating equations. Nonadjusted and adjusted models were performed to illuminate its consistency. RESULTS: Three inflection levels (HDPs of 15.01, 36.63, and 77.74) were identified which allowed to divide the descending thoracic aorta into 4 segments. The taper was consistent before and after adjusting for age, sex, height, body mass index, hypertension, smoking habits, hyperlipidemia, and diabetes. Although 1% unit of descending thoracic aorta decreases, the maximal diameter reduces to 0.007 mm (-0.025, 0.010; P = 0.414) in the segment with HDP <15.01, to 0.151 mm (-0.158, -0.145; P < 0.001) in the segment with 15.01 ≤ HDP < 36.63, to 0.038 mm (-0.040, -0.036; P < 0.001) in the segment with 36.63 < HDP ≤ 77.74; and to 0.026 mm (-0.049, -0.002; P = 0.035) in the segment with HDP > 77.74, respectively. CONCLUSIONS: The maximal diameter of descending thoracic aorta decreases gradually and consistently among individuals free of aortic diseases.
引用
- Lu W, Guo W, Liu J, et al. Consistency of Proximal-to-Distal Tapering of Descending Thoracic Aortic Diameter: Quantification Using a Novel Computer Tomography-based Assessment. Ann Vasc Surg. 2019. PMID: 30769067. doi:10.1016/j.avsg.2018.12.072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。