文献速递主动脉疾病

Zenith支架主体迁移致腹主动脉瘤破裂:一例罕见并发症

An Extremely Rare Complication: Abdominal Aortic Aneurysm Rupture Caused by Migration of a Zenith Main Body Years After Repair of the Suprarenal Stent Separation.
PubMed 文献 · J Endovasc Ther · 2019-02-25

本文报告一例72岁男性腹主动脉瘤腔内修复术后远期并发症:2000年置入Zenith支架,2013年发生肾上支架分离致Ia型内漏并追加主体,2016年因第一主体迁移至第二主体左腿远端下缘导致IIIa型内漏及动脉瘤破裂,经转换器和髂腿成功封堵,二次修复后18个月随访稳定。

要点

  • Zenith支架肾上支架分离后,主体远期迁移可导致IIIa型内漏和动脉瘤破裂。
  • 对曾处理肾上支架分离的患者,随访需警惕主体迁移及新发内漏。
  • 二次修复可使用转换器和髂腿封堵IIIa型内漏,短期随访结果稳定。

核心结论

  • Zenith支架肾上支架分离治疗后,主体远期迁移可导致腹主动脉瘤破裂。

研究设计与样本

  • 单病例报告,患者为72岁男性,2000年因肾下腹主动脉瘤行Zenith支架腔内修复。

主要发现

  • 2013年随访CT显示近端裸支架断开导致Ia型内漏,追加Zenith主体和Large Palmaz XL球囊扩张支架后内漏消失。
  • 2016年患者腹痛,急诊CT显示2000年置入的第一主体迁移至2013年追加主体左腿远端下缘,导致IIIa型内漏及动脉瘤破裂。
  • 使用转换器和髂腿成功封堵IIIa型内漏,二次修复后18个月患者状况良好,CT显示支架稳定无内漏。

临床怎么用

  • 对Zenith支架肾上支架分离处理后的患者,应长期影像随访监测主体迁移和内漏。
  • 出现腹痛等症状时需警惕动脉瘤破裂,急诊CT有助于诊断。
  • IIIa型内漏可采用转换器和髂腿进行封堵。

局限性

  • 单病例报告,结论外推受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report an unusual case of an abdominal aortic aneurysm (AAA) rupture caused by migration of a Zenith stent-graft main body years after its separation from the suprarenal stent. CASE REPORT: A 72-year-old man underwent endovascular aneurysm repair with a Zenith stent-graft for an infrarenal AAA in year 2000. At that time, a femorofemoral bypass was performed because the left external iliac and common femoral arteries were dissected during treatment. In 2013, follow-up computed tomography (CT) showed disconnection of the uncovered proximal stent, which led to a type Ia endoleak. An additional Zenith main body and Large Palmaz XL balloon-expandable stent were deployed; the endoleak disappeared. In 2016, the patient had abdominal pain, and emergency CT showed AAA rupture caused by migration of the first main body deployed in 2000 under the distal edge of the contralateral (left) leg of the additional main body from 2013, which led to a type IIIa endoleak between the 2 main bodies. A converter and iliac legs were deployed to successfully seal the type IIIa endoleak. The patient remains well 18 months after the second repair; CT scans document stable stent-grafts and no endoleak. CONCLUSION: Physicians should be aware of the potential risk for AAA rupture caused by late main body migration after treatment for suprarenal stent separation from a Zenith stent-graft.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ueda T, Tajima H, Murata S, et al. An Extremely Rare Complication: Abdominal Aortic Aneurysm Rupture Caused by Migration of a Zenith Main Body Years After Repair of the Suprarenal Stent Separation. J Endovasc Ther. 2019. PMID: 30799671. doi:10.1177/1526602819830979