升主动脉与主动脉弓顺应性的在体评估
结果显示两段顺应性无显著差异,胸主动脉瘤与穿透性溃疡患者顺应性低于创伤性破裂及急慢性夹层患者,且顺应性随年龄下降、校正年龄后与直径无关。
要点
- 升主动脉与主动脉弓顺应性无显著差异,均高于既往报道的外周血管。
- 胸主动脉瘤及穿透性溃疡患者顺应性显著低于创伤性破裂和急慢性夹层患者。
- 顺应性随年龄下降,校正年龄后与主动脉直径无关。
核心结论
- 升主动脉与主动脉弓顺应性显著高于既往报道的外周血管,胸主动脉顺应性随年龄下降且与主动脉直径无关。
主要发现
- 全部患者升主动脉平均Cd为18.4%/mm Hg,主动脉弓为16.5%/100 mm Hg,两者无显著差异。
- 胸主动脉瘤与穿透性溃疡患者顺应性显著低于创伤性破裂及急慢性夹层患者(P = 0.009)。
- 主动脉横断患者顺应性显著高于胸主动脉瘤或穿透性溃疡患者(P = 0.001)。
- 升主动脉顺应性随年龄每年下降0.44 ± 0.06(P = 0.001),主动脉弓每年下降0.41 ± 0.05(P = 0.001)。
- 校正年龄后顺应性不随直径增加(P = 0.65);7例胸降主动脉支架修复后升主动脉顺应性降至12.6%/100 mm Hg,但无统计学意义(P = 0.18)。
关键数值与推荐
- Cd计算公式为Cd = ΔD/(D • ΔP),其中ΔD为主动脉直径变化,D为舒张期直径,ΔP为脉压。
临床怎么用
- 胸主动脉腔内器械设计与长期随访应考虑升主动脉与主动脉弓顺应性随年龄下降及不同疾病间的差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Dynamic compliance (Cd) of the adult thoracic ascending and arch aorta has had limited in vivo evaluation in patients with aortic disease. This study evaluates aortic compliance using intravascular ultrasound (IVUS) across a range of thoracic aortic diseases. METHODS: Seventy-nine patients undergoing thoracic aortic endovascular procedures had Cd measurements of the ascending aorta proximal to the origin of the brachiocephalic trunk and distal to the origin of the left common carotid artery using IVUS before endograft deployment. Cd was calculated for each segment using the following equation, Cd = ΔD/(D • ΔP) where ΔD = change in aortic diameter, D = diameter in diastole, and ΔP = pulse pressure. RESULTS: Mean Cd of the ascending aorta in all patients (18.4%/mm Hg) and aortic arch (16.5 %/100 mm Hg) did not differ significantly. Compliance was significantly lower in patients being treated for thoracic aortic aneurysm and penetrating ulcer than in patients with traumatic rupture, acute and chronic dissection (P = 0.009). Compliance was significantly higher in patients with aortic transection compared with thoracic aneurysm or penetrating ulcer (P = 0.001). Compliance decreased with age by 0.44 ± 0.06 (P = 0.001) per year in the ascending aorta and 0.41 ± 0.05 (P = 0.001) per year in the aortic arch. Compliance did not increase with diameter when adjusted for age (P = 0.65). Compliance measured in the ascending aorta in 7 patients after descending thoracic aortic endograft repair decreased to 12.6%/100 mm Hg, although not significant (P = 0.18). CONCLUSIONS: Ascending and aortic arch compliance is significantly higher than reported for peripheral vessels. Thoracic aortic compliance decreases with age and is not related to aortic diameter. The results of the present study are important when considering the development of endoprosthesis devices and long-term effects on the thoracic aorta.
引用
- Tobey DJ, Reynolds TS, Kopchok GE, et al. In Vivo Assessment of Ascending and Arch Aortic Compliance. Ann Vasc Surg. 2019. PMID: 30710630. doi:10.1016/j.avsg.2018.12.060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。