Destino引导下经股动脉入路分支导管插入的BEVAR技术:技术要点与病例报告
本文报告一例53岁Marfan综合征女性胸腹主动脉瘤(TAAA)修复病例,因右腋动脉慢性闭塞、左锁骨下动脉(LSA)动脉瘤,采用Destino引导下经股动脉入路完成腹腔干分支导管插入的BEVAR技术。该方法使用Destino可调弯导引鞘配合Cook Flexor鞘,在保持稳定性的同时从股动脉入路完成分支支架输送,避免经肱/腋动脉入路。作者认为该技术可重复且有效,可作为经典分支导管插入的替代方案。
要点
- Destino引导BEVAR可经股动脉入路完成下向分支导管插入,避免肱/腋动脉入路。
- 适用于复杂主动脉弓/胸降主动脉解剖,如右腋动脉闭塞、LSA动脉瘤等。
- 使用Destino可调弯导引鞘内预弯后置入Cook Flexor鞘以稳定输送支架。
核心结论
- Destino引导BEVAR是经股动脉入路完成侧支导管插入的可重复且有效的替代方案,避免经肱/腋动脉入路。
研究设计与样本
- 技术要点与病例报告,描述1例53岁Marfan综合征女性TAAA(III型夹层动脉瘤)的BEVAR修复过程。
主要发现
- 患者右腋动脉慢性闭塞、左锁骨下动脉(LSA)呈动脉瘤样改变,腹腔干分支导管插入困难,最终以裸支架作为移植物与靶血管间桥接组件用于脊髓预处理。
- 术后2个月CTA显示LSA动脉瘤直径增加1 cm,遂计划行Destino引导BEVAR以完成裸金属支架的再衬。
- Destino引导BEVAR通过股动脉入路,将Destino可调弯导引鞘弯曲后置入较小的Cook Flexor鞘以稳定输送支架。
临床怎么用
- 在复杂主动脉弓/胸降主动脉解剖中,当经肱/腋动脉入路受限(如右腋动脉闭塞)时,可考虑Destino引导下经股动脉入路完成分支导管插入。
- 操作时在Destino可调弯导引鞘内预弯后置入较小的Cook Flexor鞘,以兼顾导管插入的灵活性与支架输送的稳定性。
局限性
- 本文为单例病例报告与技术描述,未提供与其他入路比较的疗效或安全性数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study is to report the Destino-guided branched endovascular aortic repair approach as a valid alternative to catheterization downward branches in complex aortic arch/descending thoracic anatomies. METHODS & RESULTS: A 53-year-old woman with Marfan syndrome underwent a thoracoabdominal aortic aneurysm (TAAA) repair for a type III dissecting aneurysm. A custom repair with an endograft having 3 fenestrations (for renal arteries and superior mesenteric artery) and 1 branch for the celiac trunk was planned. The right axillary artery was chronically occluded; the left subclavian artery (LSA) was aneurysmatic. The catheterization of the celiac trunk branch was demanding but ultimately a bare stent was used as a bridging component between the graft and the target vessel, for spinal cord preconditioning. At the 2-month computed tomography angiography, when planning the relining of the bare metal stent, a 1 cm increase in diameter of the LSA aneurysm was documented and therefore a Destino-guided branched endovascular aortic repair was planned. This approach consists of branch catheterization via femoral access using the Destino steerable guiding sheath inside which, after bending, a smaller Cook Flexor is placed to easily deliver the stent, while maintaining stability. CONCLUSIONS: The Destino-guided branched endovascular aortic repair is a reproducible and effective alternative to the classic catheterization of side branches via brachial/axillary access allowing their completion from a femoral access.
引用
- Orrico M, Ronchey S, Setacci C, et al. The "Destino-guided BEVAR" to Catheterize Downward Branches from a Femoral Access: Technical Note and Case Report. Ann Vasc Surg. 2019. PMID: 30684615. doi:10.1016/j.avsg.2018.09.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。