文献速递主动脉疾病

TEVAR后持续性胸段假腔的弹簧圈栓塞疗效评估

Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair.
PubMed 文献 · Ann Vasc Surg · 2019-01-24

本研究回顾性分析7例TEVAR后持续胸段假腔的B型主动脉夹层患者,接受弹簧圈栓塞(3例单纯栓塞,4例联合远端破口处理)。6个月死亡率为28.6%,随访显示仅1例(16.7%)胸主动脉回缩并假腔完全血栓化,4例(66.7%)稳定但假腔持续血流,1例继续扩张并发生主动脉食管瘘。结论认为弹簧圈栓塞促进主动脉重塑的疗效有限,尤其对于胸主动脉瘤样夹层患者。

要点

  • TEVAR后持续胸段假腔行弹簧圈栓塞的主动脉重塑率有限,仅16.7%患者出现胸主动脉回缩和假腔完全血栓化。
  • 胸主动脉瘤样夹层(≥55 mm)患者可能获益更差,需谨慎选择。
  • 术后6个月死亡率达28.6%,2例死于夹层相关事件。

核心结论

  • 弹簧圈栓塞促进TEVAR后持续性胸段假腔的主动脉重塑疗效有限,尤其在胸主动脉瘤样夹层患者中。

研究设计与样本

  • 3例胸主动脉最大径<55 mm接受单纯弹簧圈栓塞,4例胸主动脉瘤样夹层≥55 mm联合远端破口处理。

主要发现

  • 所有手术成功,无术中并发症或30天死亡,出院后2例夹层相关死亡,6个月死亡率为28.6%。
  • 6例随访CTA(中位11.2个月,范围5.6-23.5)显示:1例(16.7%)胸主动脉回缩并假腔完全血栓化。
  • 4例(66.7%)胸主动脉稳定但假腔持续血流(位于栓塞水平下方或更近端)。
  • 1例胸主动脉继续扩张并在栓塞假腔近端发生主动脉食管瘘。

临床怎么用

  • 对TEVAR后持续胸段假腔患者,弹簧圈栓塞促进主动脉重塑的作用有限,不应作为常规首选。
  • 胸主动脉瘤样夹层(≥55 mm)患者选择弹簧圈栓塞需格外谨慎,密切影像随访。

局限性

  • 回顾性单中心小样本(7例),随访时间有限且部分患者失访。
  • 缺乏对照组,无法明确弹簧圈栓塞与自然病程的差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The natural history of the thoracic false lumen after coil embolization for type B aortic dissection (TBAD) treated by previous thoracic endovascular aortic repair (TEVAR) remains a matter of debate. The aim of this study is to assess the efficacy of coil embolization in promoting thoracic aortic remodeling of TBAD with persistent thoracic false lumen after TEVAR. METHODS: Between January 2015 and December 2016, 7 consecutive TBAD patients with persistent thoracic false lumen post-TEVAR underwent coil embolization, either isolated (3 with maximum thoracic aortic diameter <55 mm) or combined with adjunctive procedure(s) specifically for distal re-entry tears (4 with thoracic aneurysmal aortic dissection ≥55 mm in diameter). Pre- and postcoiling computer tomography angiography (CTA) images were used to evaluate aortic remodeling via false lumen thrombosis status and maximum thoracic aorta diameter. RESULTS: Procedures were performed successfully in all patients, without intraoperative complications or 30-day mortality. Two dissection-related deaths occurred after hospital discharge, yielding a 6-month mortality of 28.6%. Six patients had surveillance CTA images available for analyses at median 11.2 months (range 5.6-23.5) of follow-up. Thoracic aortic shrinkage and completely thrombosed thoracic false lumen were seen in 1 patient (16.7%); thoracic aortic stabilization albeit with persistent blood flow along the false lumen below or even more proximal to the embolization in 4 patients (66.7%); and continued thoracic aortic growth and aortoesophageal fistula proximal to the embolized false lumen in 1 patient. CONCLUSIONS: In this retrospective single center experience, the efficacy of coil embolization in promoting thoracic aortic remodeling of TBAD with persistent thoracic false lumen post-TEVAR appears to be limited, especially in patients with thoracic aneurysmal aortic dissection. Further studies are warranted to inform the optimal treatment strategy.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Zhang H, Ge YY, Lu K, et al. Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair. Ann Vasc Surg. 2019. PMID: 30684608. doi:10.1016/j.avsg.2018.09.037

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。