主动脉吻合装置疗效的系统综述与荟萃分析
该系统综述与荟萃分析纳入27项研究50个队列共1260例患者,评估主动脉吻合装置(AADs)的临床效果。合并平均主动脉阻断时间为35.83分钟,IRG双侧吻合成功约半数病例。
要点
- 非IRG装置30天死亡率(1.47%)低于IRG装置(9.71%)。
- 合并平均主动脉阻断时间为35.83分钟。
- IRG装置成功完成双侧环状吻合的病例约占一半。
核心结论
- 主动脉吻合装置(AADs)的30天死亡率相对较低,非IRG组死亡率最低。
研究设计与样本
- 系统综述与荟萃分析,检索MEDLINE、Scopus、ScienceDirect和Cochrane Library至2018年2月1日。
- 纳入27项研究50个队列共1260例患者,中位年龄61.4岁(范围51-73岁),男性占68.9%。
- 82.3%的手术用于治疗急性主动脉夹层。
主要发现
- 合并平均主动脉阻断时间为35.83分钟。
- 荟萃回归显示IRG装置行双侧吻合可显著缩短主动脉阻断时间。
- IRG装置成功完成双侧环状吻合的病例约占一半。
临床怎么用
- 选择主动脉吻合装置时需权衡装置类型与30天死亡率及吻合成功率的关系。
局限性
- 研究方案存在异质性,非IRG组样本量小。
- 不同装置类型的具体并发症需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: One of the factors contributing to complications related to open repair of the aorta is the construction of a hand-sewn anastomosis. Aortic anastomotic devices (AADs), such as the intraluminal ringed graft (IRG), and the anastomotic stenting technique have been developed to perform a sutureless and less complicated anastomosis. This study performed a systematic review and meta-analysis of the literature reporting clinical use of AADs and aimed to assess, primarily, the effect of each device on 30-day overall and operation-related mortality and aortic cross-clamping time and, secondarily, the rate of successful two-sided application of the IRG device and the operation-related morbidity for each device. METHODS: An electronic search was performed using MEDLINE, Scopus, ScienceDirect, and Cochrane Library by two independent authors. Our exclusion criteria included studies incorporating fewer than three patients and studies reporting results solely from animals or in vitro testing, results solely from end-to-side anastomosis, and results solely from endarterectomy procedures. The last search date was February 1, 2018. RESULTS: A total of 41 studies were identified that reported outcomes for the use of three different device types: IRG, anastomotic stenting technique, and surgical staplers. The last two types were classified together as the non-IRG group. The meta-analysis included 27 studies with 50 cohorts incorporating 1260 patients. The median age of the incorporated patients was 61.4 years (range, 51-73 years), and 68.9% were male. The operations were performed for the treatment of acute aortic dissection in 82.3%. The pooled overall 30-day mortality rate varied by device type; IRG devices had a mean rate of all-cause mortality of 9.71%, whereas non-IRG devices were associated with a significantly (I2 = 15.78%; P for Cochrane Q test < .19) lower rate of death (1.47%). The pooled mean aortic cross-clamping time was 35.83 minutes. Metaregression showed that the performance of two-sided anastomosis with the IRG device significantly decreased the aortic cross-clamping time. However, a successful two-sided ringed anastomosis was performed in approximately half of the cases. CONCLUSIONS: Taking into account that the majority of operations were performed for the treatment of acute aortic dissection, AADs had a relatively low rate of 30-day mortality. Despite the observed heterogeneity in study protocols and the small sample size in the non-IRG group, the non-IRG group presented with the lowest 30-day mortality rate. Specific device-related complications between the different device types need further investigation.
引用
- Manolesou D, Papaioannou TG, Georgiopoulos G, et al. Α systematic review and meta-analysis of the efficacy of aortic anastomotic devices. J Vasc Surg. 2019. PMID: 30683205. doi:10.1016/j.jvs.2018.08.154
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。