文献速递慢性静脉疾病

功率、线性静脉内能量密度与回撤速度在EVLA短期成功中的相对作用

The relative roles of power, linear endovenous energy density, and pullback velocity in determining short-term success after endovenous laser ablation of the truncal saphenous veins.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2018-11-15

本研究纳入203例患者(336条消融静脉)接受1470nm EVLA,功率6-12W,前瞻性随访评估LEED、功率和回撤速度对闭合成功的预测作用。结果显示较高功率(8-12W)优于低功率(6-7W),功率 foremost(P<.001),LEED次之(P<.001),回撤速度整体不显著(P=.38),仅在LEED>26J/cm时显著(P<.001)。

要点

  • 较高功率(8-12W)比低功率(6-7W)更利于静脉闭合成功。
  • 功率是首要预测因素(P<.001),LEED次之(P<.001),回撤速度整体不显著。
  • 功率>10.34W或LEED>26.56J/cm时,成功概率≥90%。

核心结论

  • 功率和LEED是EVLA短期成功的独立重要决定因素,回撤速度仅在LEED>26J/cm时显著相关。

研究设计与样本

  • 连续203例患者(336条消融静脉)接受1470nm EVLA,功率6-12W,前瞻性临床和超声随访。

主要发现

  • 较高功率(8-12W)显著优于低功率(6-7W)的闭合成功率。
  • 单因素logistic回归显示功率>10.34W时成功概率≥90%(P<.001),LEED>26.56J/cm时成功概率≥90%(P=.001)。
  • 功率 foremost(P<.001),LEED第二(P<.001),回撤速度整体不显著(P=.38),仅在LEED>26J/cm时显著(P<.001)。
  • 多因素logistic回归确认功率(P<.040)和LEED(P<.008)显著,回撤速度不显著(P=.69)。
  • 临床副作用与功率(P=.14)、LEED(P=.71)或回撤速度(P=.39)无显著关联。

关键数值与推荐

  • 功率>10.34W或LEED>26.56J/cm时,闭合成功概率≥90%。
  • 回撤速度在LEED≤26J/cm时不显著,在LEED>26J/cm时显著(P<.001)。

临床怎么用

  • 临床可优先采用较高功率(8-12W)和较高LEED(>26.56J/cm)以提高EVLA短期闭合成功率。
  • 回撤速度的调整可能仅在较高LEED值时具有意义。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The objective of this study was to describe the relative contributions of power output, linear endovenous energy density (LEED), and pullback rate (PBR) in determining successful long-term occlusion of the truncal saphenous veins after endovenous laser ablation (EVLA). METHODS: A consecutive 203 patients (336 ablated veins) with reflux of the great saphenous vein or small saphenous vein (Clinical, Etiology, Anatomy, and Pathophysiology class C2-C6) defined by duplex ultrasound and clinical criteria were treated with 1470-nm EVLA at a power of 6 to 12 W. Prospective outcomes were evaluated in serial clinical and duplex ultrasound follow-up. Univariate logistic regression (ULR) and multivariable logistic regression modeling assessed LEED, power output, and PBR as success predictors and optimal settings for sustained closure. RESULTS: Higher power outputs (8-12 W) were significantly better than lower outputs (6-7 W) for successful closure. ULR suggested a ≥90% probability of success for power output >10.34 W (P < .001) and LEED >26.56 J/cm (P = .001). Power output was foremost (P < .001) and LEED second (P < .001), and PBR was insignificant overall (P = .38), becoming significant only at LEED values >26 J/cm (P < .001). Multivariable logistic regression confirmed both power (P < .040) and LEED (P < .008) but not PBR (P = .69) as significant determinants. Clinical side effects were not associated by ULR with power output (P = .14), LEED (P = .71), or PBR (P = .39). CONCLUSIONS: Power and LEED are separate but important determinants of short-term EVLA success. Threshold-dependent effects are observed for PBR (LEED ≤26 J/cm or ≥26 J/cm), with significant PBR correlation seen only at higher LEED values. Whereas ideal values for power and LEED differ according to the clinical scenario, our findings suggest that use of higher power outputs and greater LEED values (≥90% success probability achieved with power >10.34 W or LEED >26.56 J/cm) may yield optimal results.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Srivatsa SS, Chung S, Sidhu V, et al. The relative roles of power, linear endovenous energy density, and pullback velocity in determining short-term success after endovenous laser ablation of the truncal saphenous veins. J Vasc Surg Venous Lymphat Disord. 2018. PMID: 30448152. doi:10.1016/j.jvsv.2018.07.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。