支气管镜钳辅助复杂下腔静脉滤器回收
单中心6年回顾性研究纳入60例标准技术失败的下腔静脉滤器回收患者,使用硬质支气管镜钳辅助回收,成功率为96.7%,平均透视时间33.2分钟,共4例并发症,提示该技术安全可行。
要点
- 标准回收技术失败时,硬质支气管镜钳辅助回收成功率高达96.7%。
- 滤器倾斜、腔静脉穿透和滤器断裂可能预测需将钳辅助作为一线回收技术。
- 并发症少,但需警惕腹膜后出血、腔静脉夹层和滤器断裂迁移。
核心结论
- 硬质支气管镜钳可安全可靠地回收标准技术失败的嵌入式、断裂或倾斜的可回收下腔静脉滤器。
- 成功率高达96.7%,并发症极少。
- 滤器倾斜度、腔静脉穿透和滤器断裂可预测需将钳辅助作为一线回收技术。
研究设计与样本
- 单中心回顾性研究,经机构审查委员会批准,为期6年。
- 纳入60例连续患者(23男37女;平均年龄49.3岁,范围19-77岁),均为标准技术失败后需用硬质支气管镜钳回收下腔静脉滤器。
主要发现
- 滤器置入至取出平均停留时间565天(范围15-7366天)。
- 回收前影像显示滤器与腔静脉壁相互作用1级3/60、2级44/60、3级13/60。
- 回收前影像评估继发性倾斜<10度22例(36.7%)、10-20度26例(43.3%)、>20度12例(20%),平均倾斜13.8度(范围0-48.9度)。
- 60例中58例成功回收(96.7%),2例需二次尝试(1例因迁移至右心房,1例因患者极度不适需全身麻醉)。
- 5/60例为钳辅助圈套器回收,用钳将嵌入的钩子从周围增生腔静脉内皮中剥离。
临床怎么用
- 对于标准回收技术失败的下腔静脉滤器,可考虑使用硬质支气管镜钳辅助回收。
- 滤器倾斜度、腔静脉穿透程度和滤器断裂情况可帮助预判是否需要将钳辅助作为一线回收技术。
局限性
- 单中心回顾性研究,样本量60例,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to assess the safety, feasibility, and effectiveness of endobronchial forceps-assisted retrieval of inferior vena cava (IVC) filters when standard retrieval techniques fail. METHODS: An Institutional Review Board-approved single-center retrospective review during a 6-year period identified 60 consecutive patients (23 men and 37 women; mean age, 49.3 years; range, 19-77 years) in whom rigid endobronchial forceps were required for IVC filter retrieval after standard techniques failed. Factors affecting retrieval success, including an embedded or tilted filter, overall dwell time, filter fracture, and caval penetration, were recorded, as were success rates, procedural details, and complications. RESULTS: Mean dwell time between filter placement and removal was 565 days (range, 15-7366 days). Various IVC filters were encountered: 33 Option (Argon Medical, Frisco, Tex), 8 Celect (Cook Medical, Bloomington, Ind), 9 Günther Tulip (Cook Medical), 4 G2 and 3 Eclipse (Bard, Murray Hill, NJ), 2 OptEase (Cordis, Bridgewater, NJ), and 1 Simon Nitinol (Bard). Imaging before retrieval showed grade 1 (3/60), grade 2 (44/60), and grade 3 (13/60) filter interaction with IVC wall. The degree of secondary tilt as assessed on images acquired before attempted retrieval was <10 degrees (n = 22; 36.7%), 10 to 20 degrees (n = 26; 43.3%), and >20 degrees (n = 12; 20%), with an average tilt of 13.8 degrees (range, 0-48.9 degrees). Of the 60 filters, 58 were retrieved successfully (96.7%). Two of these required a second attempt (one because of migration into the right atrium and the other because of extreme discomfort of the patient requiring subsequent general anesthesia). Five of 60 procedures were forceps-assisted loop snare retrievals in which the forceps were used to dissect the embedded hook free from surrounding hyperplastic caval venous endothelium. Mean fluoroscopy retrieval time was 33.2 minutes (range, 10-76.9 minutes). Intraprocedural inconsequential filter fracture was observed in 10 patients. There were four complications: one retroperitoneal hemorrhage, one IVC dissection flap, and two filter fractures with subsequent migration of filter components to the right side of the heart and to the right pulmonary artery. The first two complications required hospital admission and conservative management; in the last two, the fractured and migrated filter limbs were retrieved successfully using a snare device. CONCLUSIONS: Rigid endobronchial forceps can be safely and reliably used to remove embedded, fractured, or tilted retrievable IVC filters from patients in whom standard retrieval techniques are unsuccessful. There is a high success rate and minimal complications. We propose that the degree of filter tilt, caval penetration, and filter fracture are predictive of the need for the use of forceps as a first-line retrieval technique.
引用
- Tavri S, Patel IJ, Kavali P, et al. Endobronchial forceps-assisted complex retrieval of inferior vena cava filters. J Vasc Surg Venous Lymphat Disord. 2018. PMID: 30477980. doi:10.1016/j.jvsv.2018.08.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。