文献速递主动脉疾病

三维打印展示B型主动脉夹层胸主动脉腔内修复术后十二年随访

Twelve-year Follow-up Post-Thoracic Endovascular Repair in Type B Aortic Dissection Shown by Three-dimensional Printing.
PubMed 文献 · Ann Vasc Surg · 2018-10-02

本文报告一例因复杂型B型急性主动脉夹层濒临破裂而接受胸主动脉腔内修复术(TEVAR)的患者,在12年随访期间出现多次并发症并再次干预。研究者打印患者血管的全尺寸三维模型,用于展示12年随访中的不同干预过程并作为医学教育工具。结论认为该病例显示TEVAR短期和中期有效且安全,但长期并发症支持终身CT血管造影(CTA)监测的重要性,并证实三维打印技术可作为与患者沟通和住院医师教育的工具。

要点

  • TEVAR成功隔绝了主要破口血流,但12年随访期间患者出现多次并发症并接受再次干预。
  • 该病例报告显示TEVAR治疗复杂型B型急性主动脉夹层在短期和中期随访中有效且安全。
  • 随访中观察到的长期并发症支持终身CTA监测的重要性。

核心结论

  • 该病例报告显示TEVAR治疗复杂型B型急性主动脉夹层在短期和中期随访中有效且安全,但随访中观察到的长期并发症支持终身CTA监测的重要性。
  • 该研究证实三维打印技术可作为有力工具,通过真实病例的实物分析支持与患者沟通及住院医师教育。

研究设计与样本

  • 病例报告,描述一例因复杂型B型急性主动脉夹层濒临主动脉破裂而最初接受TEVAR治疗的患者。
  • 随访期为12年,期间打印患者血管的全尺寸三维模型用于展示干预过程及医学教育。

主要发现

  • TEVAR成功隔绝了主要破口处的血流。
  • 在12年随访期间,患者出现多次并发症并接受再次干预。
  • 打印了患者血管的多种全尺寸三维模型,用于解释12年随访中的不同干预措施并作为医学教育工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Thoracic endovascular repair (TEVAR) is currently considered the therapy of choice for complicated type B acute aortic dissection (TBAAD). Although several papers have reported good outcomes at short- and medium-term follow-up, some questions still remain regarding the long-term durability and re-intervention rate during follow-up. METHODS: We describe a case of a patient originally treated with TEVAR for TBAAD complicated by impending aortic rupture. RESULTS: Endovascular repair successfully excluded the flow through the primary entry tear but during the 12-year follow-up period the patient experienced several complications and re-interventions. Various full-size three-dimensional (3D) models of the patient-specific vasculature were printed to better explain the different interventional interventions over the 12 years of follow-up and as a hands-on tool for medical education. CONCLUSIONS: The present case report, involving long-term follow-up, provides an example of the effectiveness and the safety of TEVAR for the treatment of complicated TBAAD shown at short and medium-term follow-up. However, the long-term complications that were observed in this patient during follow-up support the importance of lifelong CTA surveillance. Furthermore, this study confirms the capability of 3D printing technology as a powerful tool to support communication with patients and residents' education through the physical analysis of the real cases.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Finotello A, Marconi S, Pane B, et al. Twelve-year Follow-up Post-Thoracic Endovascular Repair in Type B Aortic Dissection Shown by Three-dimensional Printing. Ann Vasc Surg. 2018. PMID: 30287292. doi:10.1016/j.avsg.2018.07.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。