文献速递颈动脉与弓上血管

经颈动脉血运重建术中临时逆转血流不改变ROADSTER 1多中心试验先导病例的脑电活动

Temporary Reversal of Blood Flow During Transcarotid Artery Revascularization Does Not Change Brain Electrical Activity in Lead-In Cases of the ROADSTER 1 Multicenter Trial.
PubMed 文献 · J Endovasc Ther · 2018-09-07

该研究对ROADSTER 1试验中5家机构的前81例连续先导患者进行事后分析,评估经颈动脉血运重建(TCAR)中逆转血流时的脑电图变化。平均血流逆转时间12.9±8.2分钟,仅1例(1.2%)因血压波动出现轻微脑电图改变,血压升高后恢复。结论认为TCAR中临时逆转血流是安全操作,在绝大多数患者中不引起脑缺血。

要点

  • TCAR逆转血流期间平均逆转时间12.9±8.2分钟,仅1例(1.2%)出现与血压波动相关的轻微脑电图改变。
  • 术后1例(1.2%)发生卒中,1例(1.2%)发生心肌梗死,30天卒中/死亡/心肌梗死率为2.5%。
  • 包括对侧颈动脉闭塞患者在内,TCAR临时逆转血流未引起绝大多数患者的脑缺血。

核心结论

  • TCAR中临时逆转血流是安全操作,在绝大多数患者中不引起脑缺血,包括对侧颈动脉闭塞者。
  • 采用逆转血流的颈动脉支架置入可减轻脑栓塞和围手术期卒中,且无需担心脑缺血。

研究设计与样本

  • ROADSTER 1多中心试验的事后分析,纳入5家参与机构的前81例连续先导患者(平均年龄72.8±8岁;61例男性)。
  • 所有患者均有重度颈动脉狭窄[53例(59.3%)左侧;12例(14.8%)对侧闭塞]且符合颈动脉内膜切除术高危标准。
  • 三分之一患者有症状:卒中13例(16.0%)或短暂性脑缺血发作14例(17.3%)。
  • 该早期患者亚组按ROADSTER 1试验方案要求接受脑电图监测,作为检测逆转血流期间脑变化的附加安全措施。

主要发现

  • 平均血流逆转时间为12.9±8.2分钟。
  • 逆转血流期间目标平均动脉压为100 mm Hg,但7例(8.6%)患者出现低血压。
  • 1例(1.2%)患者因血压波动出现轻微脑电图改变,血压升高后恢复;未观察到其他脑电图改变。
  • 1例(1.2%)患者术后发生卒中,另1例(1.2%)术后发生心肌梗死,导致2.5%的30天卒中/死亡/心肌梗死率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate any intraoperative electroencephalographic (EEG) changes accompanying reversed flow with the ENROUTE Transcarotid Neuroprotection System during transcarotid artery revascularization (TCAR). METHODS: A post hoc analysis was performed of the first 81 consecutive lead-in patients (mean age 72.8±8 years; 61 men) enrolled in the ROADSTER 1 trial at 5 participating institutions. All patients had high-grade carotid artery stenosis [53 (59.3%) left sided; 12 (14.8%) contralateral occlusions] and high-risk criteria for carotid endarterectomy. A third had symptoms of either stroke (13, 16.0%) or transient ischemic attack (14, 17.3%). This subset of early patients underwent EEG monitoring to detect any cerebral changes during reversed flow as an added safety measure mandated by the ROADSTER 1 trial protocol. RESULTS: Mean flow reversal time was 12.9±8.2 minutes. The goal mean arterial pressure during reversed flow was 100 mm Hg, but 7 (8.6%) patients suffered hypotension. One (1.2%) patient had slight EEG changes secondary to blood pressure fluctuation; these resolved with blood pressure elevation. No other EEG changes were noted. One (1.2%) patient had a postoperative stroke and another (1.2%) had postoperative myocardial infarction (MI), leading to 2.5% 30-day stroke/death/MI rate. CONCLUSION: Temporary reversal of blood flow during TCAR is a safe maneuver and does not cause cerebral ischemia in the vast majority of patients, including those with contralateral carotid occlusion. Carotid stenting performed with reversed blood flow mitigates cerebral embolization and periprocedural stroke without concern for brain ischemia.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. King AH, Motaganahalli RL, Siddiqui A, et al. Temporary Reversal of Blood Flow During Transcarotid Artery Revascularization Does Not Change Brain Electrical Activity in Lead-In Cases of the ROADSTER 1 Multicenter Trial. J Endovasc Ther. 2018. PMID: 30191765. doi:10.1177/1526602818797986

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。