使用双侧Cook Zenith髂动脉分支装置在血管内动脉瘤修复中保留髂内动脉血流

Use of Bilateral Cook Zenith Iliac Branch Devices to Preserve Internal Iliac Artery Flow During Endovascular Aneurysm Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2018-08-31

单中心前瞻性研究纳入2010年1月至2017年9月择期植入双侧Cook Zenith髂动脉分支装置(IBD)的29例患者,评估其适应证、技术选择与结局。58个IBD中55个(95%)技术成功,无死亡;随访中4个(7%)髂内动脉分支闭塞,1年和3年估计通畅率分别为97.8%±2%和88.5%±7%。作者认为在解剖合适的筛选患者中双侧IBD植入安全有效,技术成功率和中期结局与单侧使用相似。

要点

  • 29例患者植入58个IBD,55个(95%)技术成功,无死亡。
  • 随访中4个(7%)髂内动脉分支闭塞,1年通畅率97.8%±2%、3年88.5%±7%。
  • 4例(14%)需再干预,作者认为双侧IBD在筛选患者中安全有效。

核心结论

  • 作者认为,在解剖合适的筛选患者中,双侧IBD植入是保留髂内动脉血流的安全有效技术,技术成功率和中期结局与单侧使用相似。

研究设计与样本

  • 单中心前瞻性研究,纳入2010年1月至2017年9月择期植入双侧Cook Zenith IBD的全部患者,共29例(29例男性,平均年龄64.1±10岁)。

主要发现

  • 58个IBD中48个(83%)在一次手术中植入,10个(17%)分两次手术植入(两次手术平均间隔30.4±9个月)。
  • 19例(65%)有既往或同期EVAR,其余10例(35%)有既往或同期复杂主动脉修复;平均CIA直径35.2±8 mm。
  • 58个IBD中55个(95%)技术成功,无死亡;13例(38%)手术采用腋动脉入路。
  • 随访中4个(7%)IIA分支闭塞(1例双侧闭塞、2例单侧),1年和3年估计IIA分支通畅率分别为97.8%±2%和88.5%±7%;所有迟发IIA闭塞患者均无症状。
  • 4例(14%)需再干预:2例为Ib型内漏行桥接支架延长,1例因支架内附壁血栓行髂外动脉再衬,1例因髂外动脉分支闭塞行股-股交叉旁路。

关键数值与推荐

  • 双侧IBD适用于身体活跃、解剖合适且有既往或同期胸腹主动脉瘤手术或IIA侧支循环受损的患者。

临床怎么用

  • 作者认为,对解剖合适的筛选患者,双侧IBD植入是保留IIA血流的安全有效技术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Iliac branch devices (IBD) have become a widespread option to preserve antegrade internal iliac artery (IIA) flow during endovascular aneurysm repair (EVAR). Reported experience with bilateral implantation of IBDs is limited. This study aimed to describe the indications, technical options, and outcomes with the use of bilateral IBDs. METHODS: All patients undergoing elective implantation of bilateral Cook Zenith IBD between January 2010 and September 2017 in a single centre were included. Bilateral IBD was indicated in physically active, anatomically suitable patients and those with previous or concomitant surgery for a thoraco-abdominal aortic aneurysm or impaired collateral circulation to the IIA. Data were collected prospectively. RESULTS: Twenty-nine patients (29 male, mean age 64.1 ± 10 years) were included. Of the 58 IBDs, 48 (83%) were implanted in one procedure and 10 (17%) in two procedures (mean time between procedures 30.4 ± 9 months). Nineteen patients (65%) had a previous or simultaneous EVAR and the remaining 10 (35%) a previous or simultaneous complex aortic repair. Mean CIA diameter was 35.2 ± 8 mm. Technical success was achieved in 55 of the 58 IBDs (95%) with no mortality. Axillary artery access was used in 13 (38%) procedures. During follow up, four (7%) IIA branches occluded (1 bilateral occlusion and 2 unilateral). Estimated IIA branch patency at one and three years was 97.8% ± 2% and 88.5% ± 7%, respectively. All patients with late IIA occlusion remained asymptomatic. Re-intervention was needed in four patients (14%): two bridging stent graft extensions for type Ib endoleak, one relining of the external iliac artery because of mural in-stent thrombus and one femoro-femoral crossover bypass to treat an external iliac limb occlusion. CONCLUSIONS: Bilateral implantation of IBDs is a safe and effective technique to preserve IIA flow in selected patients with suitable anatomy, showing similar technical success and mid-term outcomes to the unilateral use of the device.