文献速递主动脉疾病

对比增强三维超声评估腹主动脉瘤腔内血栓

Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2018-08-27

本研究在137例无症状腹主动脉瘤患者中,以盲法对比三维对比增强超声(3D-CEUS)与CT血管造影(CTA)测量腔内血栓(ILT)体积和厚度的效度,并评估操作者间与操作者内重复性。最终分析127对3D-CEUS/CTA图像,3D-CEUS与CTA测量ILT体积的平均差为2.2 mL(为平均体积的5%),厚度平均差为0.6 mm,重复性良好。

要点

  • 3D-CEUS与CTA测量ILT体积平均差2.2 mL(平均体积的5%),变异性范围为±10.2 mL。
  • 3D-CEUS与CTA测量ILT厚度平均差0.6 mm,变异性范围为±4.6 mm。
  • 操作者间ILT体积和厚度变异性范围分别为±8.8 mL和±2.9 mm,操作者内分别为±7.5 mL和±3.3 mm。

核心结论

  • 3D-CEUS在评估腹主动脉瘤患者ILT体积和最大厚度时,与CTA一致性良好且重复性良好。
  • 3D-CEUS是研究ILT与腹主动脉瘤增长和破裂之间潜在相互作用的有前景的研究工具。

研究设计与样本

  • 研究设计为在盲法设置下对3D-CEUS与CTA以及重复3D-CEUS测量进行计划比较。
  • 连续纳入单中心无症状腹主动脉瘤患者137例,最大直径30-55 mm,连续接受CTA和3D-CEUS评估。
  • 排除CTA失败2例和3D-CEUS结果不确定8例后,最终分析127对3D-CEUS/CTA图像。
  • 在30例子组中,由两名盲法研究者分别测量两次以确定3D-CEUS操作者间和操作者内重复性。

主要发现

  • 127例患者中24例(19%)3D-CEUS未发现ILT,其中除2例外3D-CTA分析均证实无ILT。
  • 3D-CEUS与CTA的ILT体积平均差为2.2 mL(为平均体积的5%),变异性范围为±10.2 mL。
  • 3D-CEUS与CTA的ILT厚度平均差为0.6 mm,变异性范围为±4.6 mm。
  • 3D-CEUS操作者间ILT体积和厚度测量变异性范围分别为±8.8 mL和±2.9 mm。
  • 3D-CEUS操作者内ILT体积和厚度测量变异性范围分别为±7.5 mL和±3.3 mm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The impact of intraluminal thrombus (ILT) on abdominal aortic aneurysm (AAA) progression can be investigated non-invasively by three dimensional contrast enhanced ultrasound (3D-CEUS). The aim was to validate 3D-CEUS ILT volume and thickness measurements against computed tomography angiography (CTA), and to determine inter- and intra-operator reproducibility. METHODS: The design was for a planned comparison of 3D-CEUS and CTA and of repeated 3D-CEUS measurements in a blinded set up. Consecutive patients with asymptomatic AAA (n = 137, maximum diameter 30-55 mm) from a single centre were consecutively assessed by CTA and 3D-CEUS in a blinded setup. After exclusion of failed CTA (n = 2) and inconclusive 3D-CEUS (n = 8), 127 3D-CEUS/CTA pairs were analysed by Bland-Altman plots. 3D-CEUS inter- and intra-operator reproducibility were determined in a subgroup (n = 30) measured twice by two blinded investigators. RESULTS: In 24 of 127 (19%) patients, no ILT was found on 3D-CEUS. Intraluminal thrombus absence was confirmed by 3D-CTA analysis in all but two cases. Mean ILT volume difference between 3D-CEUS and CTA was 2.2 mL (5% of mean volume) and range of variability (ROV) amounted to ± 10.2 mL. Mean ILT thickness difference was 0.6 mm with a ROV of ± 4.6 mm 3D-CEUS inter-operator variations of ILT volume and thickness measurements were low (ROV ± 8.8 mL and ±2.9 mm, respectively). The corresponding intra-operator ROVs were ±7.5 mL and ±3.3 mm, respectively. CONCLUSIONS: 3D-CEUS demonstrated good reproducibility and a good agreement with CTA when estimating ILT volume and maximum thickness in AAA patients. It is a promising research tool to investigate potential interactions between ILT, AAA growth, and rupture.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Ghulam QM, Bredahl K, Sandholt B, et al. Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg. 2018. PMID: 30166213. doi:10.1016/j.ejvs.2018.07.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。