文献速递内脏/肾动脉与血管畸形

使用为脑动脉瘤开发的血流导向装置修复颅外内脏动脉瘤/假性动脉瘤:初步结果

Extracranial Visceral Artery Aneurysms/Pseudoaneurysms Repaired with Flow Diverter Device Developed for Cerebral Aneurysms: Preliminary Results.
PubMed 文献 · Ann Vasc Surg · 2018-08-06

该报告描述了2015年1月至2017年4月期间,4例颅外内脏动脉瘤/假性动脉瘤患者(中位年龄72岁)在接受经导管栓塞或覆膜支架治疗存在禁忌或失败后,使用为脑动脉瘤开发的血流导向装置(Surpass)进行择期腔内修复的初步经验。所有装置成功释放,随访中位25个月时全部通畅且未移位,所有动脉瘤囊均缩小,无内漏或终末器官缺血征象。作者认为,当血管高迂曲和小口径妨碍覆膜支架且需维持血管通畅而禁忌栓塞时,血流导向装置可作为治疗选择,但高成本和超说明书使用要求严格选择患者。

要点

  • 随访中位25个月时,所有装置通畅且未移位,动脉瘤囊均缩小,无内漏或终末器官缺血。
  • 作者认为血流导向装置可作为特定解剖条件下内脏动脉瘤/假性动脉瘤的治疗选择,但需严格选患者。

核心结论

  • 当血管高迂曲和小口径妨碍覆膜支架且需维持血管通畅而禁忌经导管栓塞时,血流导向装置可作为治疗颅外内脏动脉瘤/假性动脉瘤的一种选择。
  • 高成本和颅外血管的超说明书使用要求准确选择适合用血流导向装置治疗内脏动脉瘤/假性动脉瘤的患者。

研究设计与样本

  • 本研究为单臂初步经验报告,纳入2015年1月至2017年4月期间接受血流导向装置(Surpass;Stryker Neurovascular,弗里蒙特,加利福尼亚州)择期腔内修复的颅外内脏动脉瘤/假性动脉瘤患者。
  • 所有患者术前接受计算机断层扫描血管造影(CTA)用于诊断和手术规划,记录动脉瘤/假性动脉瘤特征(类型、位置、大小)及载瘤动脉近端和远端直径。
  • 因经导管栓塞或覆膜支架存在禁忌或既往尝试失败,动脉瘤/假性动脉瘤通过血流导向装置进行择期腔内修复。
  • 术后6个月内和24个月进行随访CTA,评估装置通畅性和位置、动脉瘤/假性动脉瘤最大直径、囊内灌注及终末器官灌注充分性。

主要发现

  • 4例患者(2例女性;中位年龄72岁,范围64-80岁)的4个内脏动脉瘤/假性动脉瘤使用血流导向装置修复。
  • 1例患者为颈部动脉吻合口假性动脉瘤,其余为2个脾动脉瘤和1个肝总动脉瘤。
  • 动脉瘤/假性动脉瘤中位大小20 mm(范围13-26 mm),载瘤动脉中位口径5 mm(范围3-5 mm)。
  • 所有病例装置均正确释放;2/4个动脉瘤/假性动脉瘤在手术结束时显示内漏。
  • 术后中位25个月(范围4-28个月)的随访CTA显示,所有装置通畅且未移位,所有动脉瘤/假性动脉瘤囊均缩小,无内漏或终末器官缺血征象。

临床怎么用

  • 作者认为,当血管高迂曲和小口径妨碍覆膜支架且需维持血管通畅而禁忌经导管栓塞时,血流导向装置可考虑用于治疗颅外内脏动脉瘤/假性动脉瘤。
  • 作者指出,高成本和颅外血管的超说明书使用要求准确选择适合用血流导向装置治疗内脏动脉瘤/假性动脉瘤的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recently, there has been a shift toward elective endovascular repair of visceral artery aneurysms (VAAs). Transcatheter embolization (TE) and covered stenting (CS) represent the 2 most used endovascular techniques; however, TE carries the potential risk of end-organ ischemia, while CS is challenging when the parent arteries are tortuous. Flow diverter devices (FDDs) developed for cerebral aneurysms maintain distal flow and are characterized by high navigability in tortuous arteries. This report describes our initial experience in using FDD developed for cerebral aneurysms to treat extracranial VAAs/pseudoaneurysm (VAP). METHODS: The study was conducted on patients affected by VAP, who underwent endovascular repair using FDD, between January 2015 and April 2017. All patients underwent preinterventional computed tomography angiography (CTA) for diagnosis and procedural planning. VAP features (type, location, size) and the diameter of both the proximal and distal parent arteries were recorded. Since TE or CS was contraindicated or failed in the previous attempt, VAPs were repaired through an elective endovascular procedure with FDD (Surpass; Stryker Neurovascular, Fremont, CA). Follow-up CTAs were performed within 6 months and at 24 months after the endovascular repair, evaluating patency and proper position of the FDD, the maximum diameter of the VAP, any perfusion of the sac, and adequacy of end-organ perfusion. RESULTS: Four VAPs were repaired by FDD in 4 patients (2 females; median age: 72 years, range: 64-80 years). One patient suffered from cervical arterial anastomotic pseudoaneurysm, whereas the remaining VAPs were 2 splenic artery aneurysms and 1 common hepatic aneurysm. VAPs median size was 20 mm (range: 13-26 mm) with median parent artery caliber of 5 mm (range: 3-5 mm). The correct deployment of the device was obtained in all cases; 2/4 VAPs showed endoleak at the end of the procedure. At follow-up CTAs performed after the procedure in a median time of 25 months (range: 4-28 months), all devices were patent and not migrated. All VAPs showed shrinkage of the sac without endoleak or signs of end-organ ischemia. CONCLUSIONS: When high tortuosity and small caliber of the parent arteries prevent CS and the necessity to maintain vessel patency contraindicates TE, FDD could represent an option for the treatment of VAP; however, high costs and the off-label use in extracranial vessels demand an accurate selection of the patients suitable for the VAP treatment with FDD.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Colombi D, Bodini FC, Bossalini M, et al. Extracranial Visceral Artery Aneurysms/Pseudoaneurysms Repaired with Flow Diverter Device Developed for Cerebral Aneurysms: Preliminary Results. Ann Vasc Surg. 2018. PMID: 30092438. doi:10.1016/j.avsg.2018.05.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。