文献速递血液透析通路

桡动脉直径预测动静脉瘘二次通畅率的最佳截断值及影响因素

Optimal Cutoff Values for Radial Artery Diameter in Secondary Patency Rates and Risk Factors Affecting of Arteriovenous Fistulas.
PubMed 文献 · Ann Vasc Surg · 2018-08-04

单中心回顾性研究纳入2008年3月至2013年4月在本院行动静脉瘘手术且术前有超声检查的204例患者,计算1、3、5年二次通畅率分别为78.9%、69.8%、67.4%,桡动脉直径和年龄≥65岁为显著危险因素,桡动脉直径截断值为2.0 mm。

要点

  • 1、3、5年二次通畅率分别为78.9%、69.8%、67.4%。
  • 桡动脉直径和年龄≥65岁是二次通畅率的显著危险因素。
  • 桡动脉直径预测二次通畅率的截断值为2.0 mm。

核心结论

  • 桡动脉直径截断值2.0 mm可能提高动静脉瘘的二次通畅率,该结果与既往报道的初次通畅率桡动脉直径一致,是具有临床意义的指标。

研究设计与样本

  • 单中心回顾性研究,纳入2008年3月至2013年4月在本院行动静脉瘘手术、术前接受超声检查且二次通畅数据可用的204例患者。

主要发现

  • 1年、3年、5年二次通畅率分别为78.9%、69.8%、67.4%。
  • 对数秩检验显示桡动脉直径和年龄≥65岁为显著危险因素。
  • 时依ROC曲线分析显示桡动脉直径截断值为2.0 mm。

关键数值与推荐

  • 桡动脉直径截断值为2.0 mm。
  • 年龄≥65岁为二次通畅率的显著危险因素。

临床怎么用

  • 术前超声测量桡动脉直径,以2.0 mm作为预测动静脉瘘长期二次通畅率的截断值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Radial artery diameter on preoperative ultrasound has previously been investigated as a risk factor for the primary patency rate of arteriovenous fistulas. However, the cutoff values for long-term secondary patency rates have not been reported in detail. The present study verified the cutoff values that predict long-term secondary patency. METHODS: This was a single-center retrospective study. Among the arteriovenous fistula operations performed at our hospital from March 2008 to April 2013, 204 patients who underwent ultrasonography prior to the operation and whose secondary patency data were available were enrolled in this study. Secondary patency rates were calculated at 1, 3, and 5 years. Risk factors, including radial artery diameters (divided into quartiles), age, sex, diabetes mellitus, calcification, right versus left radial artery, and operative time (divided into quartiles) were examined using the log-rank test. Next, we performed multivariate Cox proportional hazard analysis using risk factors that were significant in the log-rank test. Further studies using time-dependent receiver operating characteristic curves were conducted to examine the cutoff values for radial artery diameters. RESULTS: The 1-, 3-, and 5-year secondary patency rates were 78.9%, 69.8%, and 67.4%, respectively. Significant risk factors included radial artery diameter and age ≥65 years. The cutoff value was 2.0 mm. CONCLUSIONS: A radial artery diameter cutoff value of 2.0 mm may increase the secondary patency rate of arteriovenous fistulas. This result agrees with the radial artery diameter reported for primary patency rates and is a clinically significant indicator.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Utsunomiya H, Fukuya Y, Sotozaki N, et al. Optimal Cutoff Values for Radial Artery Diameter in Secondary Patency Rates and Risk Factors Affecting of Arteriovenous Fistulas. Ann Vasc Surg. 2018. PMID: 30081172. doi:10.1016/j.avsg.2018.05.050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。