文献速递血液透析通路

体内动静脉瘘非平面性与动脉曲率的异质性研究

Heterogeneity in the nonplanarity and arterial curvature of arteriovenous fistulas in vivo.
PubMed 文献 · J Vasc Surg · 2018-07-29

该观察性研究于2013至2016年纳入60例上肢动静脉瘘患者,术中行相位对比磁共振成像获取管腔几何,分析三维几何与6周成熟的关系。结果显示动脉非平面性和曲率存在显著异质性,头臂型较桡头型更明显;动脉非平面性增加和分叉角度增大与成熟率更高相关,瘘位置亦相关。

要点

  • 动静脉瘘动脉非平面性和曲率存在显著异质性,头臂型较桡头型更明显。
  • 动脉非平面性每增加0.1/血管直径,logOR为0.95(95%CI 0.22-1.90,P=0.03),与成熟率更高相关。
  • 分叉角度每增加1度,logOR为0.05(95%CI 0.01-0.09,P=0.02),与成熟率更高相关。

核心结论

  • 动静脉瘘三维几何存在显著异质性,尤其动脉非平面性和曲率。
  • 个体几何特征对成熟的影响尚不确定,但支持未来建模研究需考虑动静脉瘘复杂几何的 premise。

研究设计与样本

  • 观察性研究,2013至2016年纳入60例按当前手术最佳实践创建上肢动静脉瘘的患者。
  • 手术当日行相位对比磁共振成像获取管腔几何,并行超声测量流量。
  • 对磁共振成像数据集进行分割和重建,用于局部几何的定量和定性分析。
  • 术后6周评估临床成熟;20例患者于2周时重复成像。

主要发现

  • 60例成功成像,包括桡头型(n=17)、头臂型(n=40)和臂贵要型(n=3)瘘。
  • 从分割血管腔提取的中心线显示动脉非平面性和曲率存在显著异质性,且头臂型较桡头型更明显。
  • 全队列投影分叉角度为73±16度(均值±标准差)。
  • 20例重复成像患者中,2周时几何形态保持。
  • 动脉非平面性更大(每0.1/血管直径的logOR为0.95,95%CI 0.22-1.90,P=0.03)和分叉角度更大(每度的logOR为0.05,95%CI 0.01-0.09,P=0.02)与成熟率更高相关;瘘位置(上臂 vs 前臂,logOR为-1.9,95%CI -3.2至0.7,P=0.002)亦相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Native arteriovenous fistulas (AVFs) for hemodialysis are susceptible to nonmaturation. Adverse features of local blood flow have been implicated in the formation of perianastomotic neointimal hyperplasia that may underpin nonmaturation. Whereas computational fluid dynamic simulations of idealized models highlight the importance of geometry on fluid and vessel wall interactions, little is known in vivo about AVF geometry and its role in adverse clinical outcomes. This study set out to examine the three-dimensional geometry of native AVFs and the geometric correlates of AVF failure. METHODS: As part of an observational study between 2013 and 2016, patients underwent creation of an upper limb AVF according to current surgical best practice. Phase-contrast magnetic resonance imaging was performed on the day of surgery to obtain luminal geometry along with ultrasound measurements of flow. Magnetic resonance imaging data sets were segmented and reconstructed for quantitative and qualitative analysis of local geometry. Clinical maturation was evaluated at 6 weeks. RESULTS: There were 60 patients who were successfully imaged on the day of surgery. Radiocephalic (n = 17), brachiocephalic (n = 40), and brachiobasilic (n = 3) fistulas were included in the study. Centerlines extracted from segmented vessel lumen exhibited significant heterogeneity in arterial nonplanarity and curvature. Furthermore, these features are more marked in brachiocephalic than in radiocephalic fistulas. Across the cohort, the projected bifurcation angle was 73 ± 16 degrees (mean ± standard deviation). Geometry was preserved at 2 weeks in 20 patients who underwent repeated imaging. A greater degree of arterial nonplanarity (log odds ratio [logOR], 0.95 per 0.1/vessel diameter; 95% confidence interval [CI], 0.22-1.90; P = .03) and a larger bifurcation angle (logOR, 0.05 per degree; 95% CI, 0.01-0.09; P = .02) are associated with a greater rate of maturation, as is fistula location (upper vs lower arm; logOR, -1.9; 95% CI, -3.2 to 0.7; P = .002). CONCLUSIONS: There is significant heterogeneity in the three-dimensional geometry of AVFs, in particular, arterial nonplanarity and curvature. In this largest cohort of AVF geometry to date, the effect of individual geometric correlates on maturation is uncertain but supports the premise that future modeling studies will need to acknowledge the complex geometry of AVFs.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Corbett RW, Grechy L, Iori F, et al. Heterogeneity in the nonplanarity and arterial curvature of arteriovenous fistulas in vivo. J Vasc Surg. 2018. PMID: 30064838. doi:10.1016/j.jvs.2018.04.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。