复杂性B型主动脉夹层血管内修复后的晚期主动脉重塑——TEVAR仅保护胸主动脉覆盖段
本研究回顾性分析2004至2012年间在本中心接受TEVAR治疗的23例复杂性B型主动脉夹层患者,基于术前及末次随访CT血管造影评估胸腹主动脉重塑。结果显示主动脉直径仅在B水平显著增加,真腔面积在A、B、C、D水平均显著增加,假腔面积仅在A、B水平显著减少;结论认为TEVAR是保护胸主动脉的安全有效方法,80%病例无需额外远端主动脉覆盖。
要点
- 真腔面积在A、B、C、D四个水平均显著增加。
- 假腔面积仅在A、B水平显著减少,C、D水平无变化。
核心结论
- TEVAR治疗复杂性急性B型主动脉夹层是保护胸主动脉的安全有效方法。
- 该手术在多数患者中有效,80%的病例无需额外远端主动脉覆盖。
- 在复杂性B型主动脉夹层的长期观察中,腹主动脉相对稳定。
研究设计与样本
- 回顾性分析2004至2012年间在本中心接受TEVAR治疗的23例复杂性B型主动脉夹层患者。
- 基于术前及末次随访CT血管造影评估主动脉重塑,测量左支气管、膈肌、腹腔干及肾动脉以下水平的主动脉直径、总主动脉面积、真腔面积和假腔面积。
主要发现
- 技术成功率为100%,临床成功率为82.6%。
- 早期死亡率为13%(3例患者)。
- 平均随访57.9个月(范围26-123个月;标准差±30.5),所有患者均完成随访。
- 总主动脉面积仅在A水平稳定,在B、C、D水平显著增加;真腔面积在A、B、C、D水平均显著增加;假腔面积在A、B水平显著减少,在C、D水平无变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: TEVAR is the preferred way of treatment of complicated type B aortic dissection. The purpose of the study was to assess the impact of TEVAR on aortic remodeling in the thoracic and abdominal segment in long-term follow-up. METHODS: Twenty-three patients with complicated type B aortic dissection were treated by TEVAR in years 2004-2012 in our department. Aortic remodeling was rated based on preoperative and final follow-up computed tomography angiography. Aorta was measured at the level of left bronchus, the diaphragm, celiac trunk, and the aorta below the renal arteries. Diameter of the aorta (da), total aortic area (taa), true lumen area (tla), and false lumen area (fla) were measured. RESULTS: Primary technical success was obtained in 100%. Primary clinical success rate was 82.6%. Early mortality was 13% (3 patients). Mean follow-up was 57.9 months (26-123; standard deviation, ±30.5). All patients remain in the follow-up. Diameter of the aorta increased significantly only at the B level-from baseline 35,6 mm to 40,5 mm in the follow-up (P = 0.005). Total aortic area (taa) was stable only at the A level but increased significantly at the B, C, and D levels. Area of the true lumen (tla) increased significantly at A, B, C, and D levels; area of false lumen (fla) decreased significantly at A and B levels, but the area of false lumen (fla) did not change at C and D levels. CONCLUSIONS: TEVAR for complicated acute aortic type B dissection is a safe and effective method of protecting thoracic aorta. The procedure was effective in majority of patients, and in 80% of the cases, there was no need for additional distal aortic coverage. The abdominal aorta is relatively stable over a long period of observation in complicated type B aortic dissection.
引用
- Wojciechowski J, Znaniecki L, Kaszubowski M, et al. Late Aortic Remodeling after Endovascular Repair of Complicated Type B Aortic Dissection-TEVAR Protects Only the Covered Segment of Thoracic Aorta. Ann Vasc Surg. 2018. PMID: 30081168. doi:10.1016/j.avsg.2018.05.057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。