文献速递主动脉疾病内脏/肾动脉与血管畸形

多层支架治疗肾旁主动脉瘤的血流动力学与氧传输:数值研究

Hemodynamics and Oxygen Transport through Pararenal Aortic Aneurysm Treated with Multilayer Stent: A Numerical Study.
PubMed 文献 · Ann Vasc Surg · 2018-08-03

本研究通过数值模拟对比无支架、单层及双层支架治疗肾旁主动脉瘤的3例模型,评估多层支架的可行性与最佳支架密度。结果显示支架植入后瘤囊内血流速度下降但瘤壁压力未降低,双层支架下分支血管流量仍高于正常,预测最佳孔隙率约为49.9%。作者认为多层支架不能可行地应用于高风险肾旁主动脉瘤,但可诱导瘤囊后期血栓形成并维持内脏血管通畅,结果提示最佳支架可能为4层支架。

要点

  • 支架植入后瘤囊内血流速度下降,但瘤壁压力未降低,仅分布更均匀。
  • 支架植入后低壁面剪切应力与低舍伍德数的双低区域扩大。
  • 即使双层支架,分支血管流量仍高于正常,预测最佳孔隙率约49.9%。

核心结论

  • 与既往研究不同,多层支架不能可行地应用于高风险肾旁主动脉瘤。
  • 多层支架可诱导瘤囊后期血栓形成并维持内脏血管通畅,结果提示最佳支架可能为4层支架。

研究设计与样本

  • 本研究通过数值模拟检查3例模型(无支架、单层支架和双层支架),以探索多层支架治疗此类动脉瘤的可行性并估计是否存在更合适或最佳的支架密度。

主要发现

  • 支架干预后瘤囊内血流速度下降,但瘤壁表面压力未降低,尽管压力变得更均匀。
  • 支架植入后双低区域(低壁面剪切应力和低舍伍德数)扩大。
  • 即使使用双层支架,分支血管流量仍高于正常。
  • 预测最佳支架孔隙率约为49.9%。

临床怎么用

  • 作者认为多层支架不能可行地应用于高风险肾旁主动脉瘤。
  • 作者指出多层支架可诱导瘤囊后期血栓形成并维持内脏血管通畅,结果提示最佳支架可能为4层支架。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As opposed to an endoluminal stent graft, a multilayer stent (MS) consists of a porous mesh, which allows for the possibility of treating pararenal aortic aneurysms (PRAAs) that involve a significant branch vessel. However, the choice of the density of the MS plays a vital role in isolating the aneurysm and allowing unobstructed blood flow in the branch vessel. METHOD: In the present study, we examined 3 cases (without a stent and with single-layer and double-layer stents) via numerical simulations to explore the feasibility of the MSs used in the treatment of such aneurysms and estimate whether there is a more appropriate or optimal stent density. RESULTS: With stent intervention, the velocity of blood flow in the sac decreased, but the pressure on the surface of the aneurysm did not decrease although it became more uniform. In addition, the "region of double low" (with low wall shear stress and a low Sherwood number) enlarged after stent implantation. Even with the double-layer stent, however, the flux of the branch vessel was still above normal, and we could predict that the optimal stent porosity was approximately 49.9%. CONCLUSIONS: Unlike in previous studies, an MS could not be feasibly applied to high-risk PRAAs. However, an MS can induce sac thrombosis in the later stages while maintaining visceral vessel patency, and our results suggest that the optimal stent may be a 4-layer stent.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Li Z, Yan F, Yang J, et al. Hemodynamics and Oxygen Transport through Pararenal Aortic Aneurysm Treated with Multilayer Stent: A Numerical Study. Ann Vasc Surg. 2018. PMID: 30081175. doi:10.1016/j.avsg.2018.05.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。