不完整Willis环与颈动脉外翻式内膜剥脱术无分流时围手术期神经事件发生率升高相关
该研究前瞻性收集2013至2015年间902例全身麻醉下颈动脉内膜剥脱术患者的临床资料,最终纳入545例分析。结果显示孤立大脑中动脉是术后即刻神经事件的独立预测因素(比值比11.12,95%CI 3.57-35.87,P<.001),作者建议此类患者常规分流以预防神经事件。
要点
- 孤立大脑中动脉患者术后即刻神经事件发生率为24%(8/34),其中短暂性脑缺血发作6例、卒中2例。
- 孤立大脑中动脉是即刻神经事件的独立预测因素,比值比11.12(95%CI 3.57-35.87,P<.001)。
- 在孤立大脑中动脉患者中,仅症状性患者存在显著风险(比值比3.34,95%CI 1.19-9.73,P=.02)。
核心结论
- 孤立大脑中动脉使颈动脉内膜剥脱术无分流阻断期间即刻神经事件风险增加10倍以上。
- 作者建议此类患者常规采用分流以预防即刻神经事件。
研究设计与样本
- 前瞻性收集2013至2015年间902例全身麻醉下颈动脉内膜剥脱术患者的临床资料和结局。
- 排除分流术患者35例及颅内影像不足以评估Willis环者322例,最终纳入545例(男性331例,平均年龄69±8岁)。
- 计算机断层扫描血管成像由两名对治疗结局不知情的血管放射科医生独立回顾性审阅。
主要发现
- 545例患者中术后发生卒中12例(2.2%),即刻神经事件共20例(卒中8例、短暂性脑缺血发作12例)。
- 完整Willis环仅见于19例(3.5%),孤立大脑中动脉见于34例(6.3%)。
- 至少一条侧支循环完整者330例中仅观察到4例即刻神经事件(1.2%)。
- 孤立大脑中动脉34例中8例(24%)发生即刻神经事件(短暂性脑缺血发作6例、卒中2例)。
- 孤立大脑中动脉为即刻神经事件的独立预测因素(比值比11.12,95%CI 3.57-35.87,P<.001)。
关键数值与推荐
- 影像评估将Willis环各段分类为正常、发育不良(直径<0.8 mm)或缺失。
- 同侧大脑中动脉若对侧颈动脉或后循环的前交通支和后交通支均缺失则视为孤立。
- 即刻神经事件定义为术后立即诊断的任何短暂性脑缺血发作和卒中。
临床怎么用
- 作者建议对孤立大脑中动脉患者常规采用分流以预防即刻神经事件。
- 在孤立大脑中动脉患者中,仅症状性患者存在显著风险(比值比3.34,95%CI 1.19-9.73,P=.02),其余参数均无显著性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: A complete circle of Willis (CoW) is considered an important collateral network to maintain blood flow during cross-clamping in carotid endarterectomy (CEA). The aim of this study was to evaluate the impact of an incomplete CoW with isolated middle cerebral artery (iMCA) on immediate neurologic events (INEs) after CEA. METHODS: We prospectively collected the clinical data and outcomes of 902 patients who underwent CEA under general anesthesia between 2013 and 2015. All patients had preoperative computed tomography angiography of the extracranial and intracranial cerebral circulation. Indications were asymptomatic (52%) and symptomatic (48%) carotid artery disease. Patients who had CEA with shunt (n = 35) and those with inadequate intracranial imaging to assess CoW were excluded (n = 322) only. Computed tomography angiography images were reviewed retrospectively and independently by two vascular radiologists who were blinded for treatment outcomes. Imaging assessment included the vertebral and carotid circulation and each segment of the CoW, which was classified as normal, hypoplastic (diameter < 0.8 mm) or absent. The ipsilateral MCA was considered isolated if there was an absence of the anterior and posterior communicating branches from the contralateral carotid or posterior circulations. INE was defined as any transient ischemic attack (TIA) and stroke diagnosed immediately after the procedure. RESULTS: Of the 545 included patients (331 males; mean age, 69 ± 8 years), 12 (2.2%) had a stroke in the postoperative period. There were 20 INEs (8 strokes and 12 TIAs). A complete CoW was rare; it was only detected in 19 patients (3.5%) and an iMCA was found in 34 patients (6.3%). When at least one collateral circulation was complete (in 330 patients), we observed only four INEs (1.2%). Of the 34 patients with an iMCA, 8 (24%) had INE (6 TIAs and 2 strokes). Overall, iMCA was an independent predictor of INEs (odds ratio, 11.12; 95% confidence interval, 3.57-35.87; P < .001). With logistic regression, the model included hypertension, smoking, diabetes, hyperlipidemia, carotid clamping time (minutes), contralateral significant internal carotid artery stenosis of greater than 90%, ipsilateral significant internal carotid artery stenosis of greater than 90%, preoperative symptoms in 6 months, and iMCA; above iMCA only symptomatic patients had significant risk (odds ratio, 3.34; 95% confidence interval, 1.19-9.73; P = .02), whereas all other parameters were not significant. CONCLUSIONS: An iMCA carries more than a 10-fold higher the risk of INEs after CEA with cross-clamping without shunt protection. In these patients, routine shunting is recommended to prevent INEs.
引用
- Banga PV, Varga A, Csobay-Novák C, et al. Incomplete circle of Willis is associated with a higher incidence of neurologic events during carotid eversion endarterectomy without shunting. J Vasc Surg. 2018. PMID: 29983353. doi:10.1016/j.jvs.2018.03.429
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。