高壁应力可能预测胸主动脉腔内修复术后支架移植物诱发新破口形成
本文通过两例慢性或亚急性B型夹层患者TEVAR术后CT随访,结合形态学与有限元分析,发现发生SINE的患者支架移植物迂曲度更高且SINE远端邻近区域壁应力更高,提示高迂曲度导致高壁应力可能与SINE形成有关,但需进一步大样本研究证实。
要点
- 两例TEVAR术后患者中,发生SINE者支架移植物迂曲度高于未发生者。
- SINE患者SINE远端邻近区域壁应力远高于未发生SINE者。
- 高支架移植物迂曲度可导致高壁应力,可能与SINE形成有关。
核心结论
- 本病例研究提示高支架移植物迂曲度可导致高壁应力,后者可能与SINE形成有关,需进一步大样本研究证实这一初步发现。
研究设计与样本
- 病例报告,纳入两例因B型夹层行TEVAR的女性患者(患者1年龄59岁,慢性期;患者2年龄44岁,亚急性期),基于首次随访CT图像进行形态学与有限元分析。
主要发现
- 3个月随访CT显示两例患者假腔血栓形成程度不一;14个月随访时患者1出现SINE,患者2夹层主动脉保持稳定。
- 计算结果显示,发生SINE的患者支架移植物迂曲度高于未发生SINE的患者,且SINE远端邻近区域壁应力远高于未发生SINE者。
局限性
- 原文指出需进一步大样本研究证实这一初步发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To explore the potential role of morphological factors and wall stress in the formation of stent-graft-induced new entries (SINE) based on computed tomography (CT) images after thoracic endovascular aortic repair (TEVAR). CASE REPORT: Two female patients aged 59 years (patient 1) and 44 years (patient 2) underwent TEVAR for type B dissection in the chronic (patient 1) or subacute (patient 2) phase. CT scans at 3-month follow-up showed varying degrees of false lumen thrombosis in both patients. At 14-month follow-up, a SINE was observed in patient 1 while the dissected aorta in the other patient remained stable. Morphological and finite element analyses were performed based on the first follow-up CT images. The computational results showed that the SINE patient had higher stent-graft tortuosity than the non-SINE patient and much higher wall stress in the region close to the distal SINE. CONCLUSION: This case study suggests that high stent-graft tortuosity can lead to high wall stress, which is potentially linked to the formation of SINE. Further large population-based studies are needed to confirm this preliminary finding.
引用
- Menichini C, Pirola S, Guo B, et al. High Wall Stress May Predict the Formation of Stent-Graft-Induced New Entries After Thoracic Endovascular Aortic Repair. J Endovasc Ther. 2018. PMID: 30056791. doi:10.1177/1526602818791827