植入18年后采用新型取出方法取出永久性VenaTech LGM滤器一例
本文报告一例植入18年的永久性VenaTech LGM下腔静脉滤器成功取出的病例,采用新型取出技术,滤器锥形部分完整取出,垂直支柱有意保留于腔静脉壁外血管外。
要点
- 永久性VenaTech LGM滤器已停产但仍有大量患者体内植入。
- 一例植入18年后采用新型技术成功取出该滤器的病例。
- 滤器锥形部分完整取出,垂直支柱有意保留于腔静脉壁外。
核心结论
- 采用新型取出方法可成功取出植入18年的永久性VenaTech LGM下腔静脉滤器,滤器锥形部分完整取出,垂直支柱有意保留于腔静脉壁外血管外。
研究设计与样本
- 病例报告:一例植入永久性VenaTech LGM下腔静脉滤器18年、滤器置入指征已不存在的患者,采用新型取出技术取出滤器。
主要发现
- 滤器锥形部分完整取出,垂直支柱有意保留于腔静脉壁外血管外。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The VenaTech LGM (B. Braun, Melsungen, Germany) inferior vena cava (IVC) filter was designed as a permanent IVC filter to prevent clot migration and pulmonary embolism. This filter has been discontinued, but thousands remain implanted within patients who incur the added long-term risks of an indwelling IVC filter. We present a case of successful removal of a permanent VenaTech LGM IVC filter using a novel technique in a patient in whom filter placement was no longer indicated. The conical portion of the filter was removed intact, and the vertical struts were intentionally left embedded extravascularly within the caval wall.
引用
- Ahmed O, Hadied MO, Madassery S, et al. Retrieval of a permanent VenaTech LGM filter 18 years after implantation using a novel removal method. J Vasc Surg Venous Lymphat Disord. 2018. PMID: 29909858. doi:10.1016/j.jvsv.2018.04.003