在重度颈动脉狭窄中剪切率是比流速或直径更好的症状性缺血性脑血管事件标志物
本研究为病例对照研究,纳入1年内经双功能超声识别的大于70%颈内动脉狭窄患者308例(无症状209例、有症状99例),比较剪切率、流速和直径对症状性缺血性脑血管事件的诊断价值。结果发现有症状患者平均剪切率为9338 s-1,无症状者为7930 s-1,剪切率≥8000 s-1者出现症状的比值比为12.1(95%CI 6.12-24.09),灵敏度84.8%、特异度61.2%。作者认为剪切率≥8000 s-1可作为症状性缺血性脑血管事件的预测指标,但需进一步验证。
要点
- 剪切率≥8000 s-1者出现症状的比值比为12.1(95%CI 6.12-24.09),灵敏度84.8%、特异度61.2%。
- 有症状患者平均剪切率为9338 s-1,无症状者为7930 s-1。
- 作者认为剪切率≥8000 s-1可作为症状性缺血性脑血管事件的预测指标。
核心结论
- 在大于70%颈内动脉狭窄患者中,剪切率与症状性脑血管缺血事件的患病率相关。
- 剪切率≥8000 s-1或可作为出现症状性脑血管缺血事件的预测指标。
- 作者认为需要进一步验证以及进一步研究高剪切率与缺血性脑血管事件之间的病理机制。
研究设计与样本
- 病例对照研究,纳入经双功能超声识别的大于70%颈内动脉狭窄患者308例(男性55.5%,平均年龄73±10岁)。
- 有症状患者纳入研究组,无症状患者作为对照组。
- 剪切率由高分辨率超声图像计算得出。
- 采用描述性统计以及单因素和多因素分析校正混杂因素,并用受试者工作特征曲线比较剪切率、流速和颈内动脉直径的诊断价值。
主要发现
- 研究共纳入308例患者,其中无症状209例、有症状99例。
- 无症状患者平均剪切率为7930 s-1,有症状患者为9338 s-1。
- 受试者工作特征曲线确定区分有症状与无症状患者的剪切率截断值为8000 s-1。
- 剪切率<8000 s-1者中无症状占92%、有症状占8.0%;剪切率≥8000 s-1者中无症状占48.5%、有症状占51.5%。
- 剪切率高于该截断值者出现症状的可能性是剪切率<8000 s-1者的12倍(比值比12.1;95%CI 6.12-24.09),灵敏度84.8%、特异度61.2%。
关键数值与推荐
- 剪切率截断值8000 s-1用于区分有症状与无症状患者。
- 剪切率≥8000 s-1者出现症状的比值比为12.1(95%CI 6.12-24.09)。
- 剪切率诊断症状性事件的灵敏度为84.8%、特异度为61.2%。
临床怎么用
- 在大于70%颈内动脉狭窄患者中,剪切率与症状性脑血管缺血事件的患病率相关。
- 作者认为剪切率≥8000 s-1或可作为出现症状性脑血管缺血事件的预测指标。
局限性
- 作者认为需要进一步验证。
- 作者认为需要进一步研究高剪切率与缺血性脑血管事件之间的病理机制。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study was designed to test the hypothesis that the high shear rate of flow in the area of carotid stenosis is associated with the incidence of ischemic symptoms in patients with a high degree of carotid stenosis. METHODS: This is a case-control study of patients with >70% stenosis of the internal carotid artery (ICA) identified by duplex ultrasound in an Intersocietal Accreditation Commission-accredited laboratory during 1 year. Symptomatic patients were included in the study group, and asymptomatic patients served as controls. Shear rates were calculated from high-resolution ultrasound images. Descriptive statistics and univariate and multivariate analysis were performed to account for confounding factors. Receiver operating characteristic curves were used to compare diagnostic values of shear rate, velocities, and diameters of the ICA. RESULTS: The study included 308 patients (55.5% male; mean age, 73 ± 10 years); 209 of them were asymptomatic and 99 were symptomatic. The mean shear rate was 7930 s-1 for asymptomatic and 9338 s-1 for symptomatic patients. Receiver operating characteristic curve identified a cutoff value of 8000 s-1 to differentiate between symptomatic and asymptomatic patients; 92% of asymptomatic patients and 8.0% of symptomatic patients had a shear rate of <8000 s-1 compared with 48.5% asymptomatic and 51.5% symptomatic who had a shear rate ≥8000 s-1. Patients who had a shear rate higher than this cutoff value were 12 times more likely to be symptomatic than those with a shear rate <8000 s-1 (odds ratio, 12.1; 95% confidence interval, 6.12-24.09). Sensitivity and specificity were 84.8% and 61.2%, respectively. CONCLUSIONS: In patients with >70% ICA stenosis, the shear rate is associated with the prevalence of symptomatic cerebrovascular ischemic events. A shear rate of 8000 s-1 and above may be used as a predictor for having symptomatic cerebrovascular ischemic events. Further validation as well as further study of the pathologic mechanism connecting the high shear rate and ischemic cerebrovascular events is needed.
引用
- Hariri N, Russell T, Kasper G, et al. Shear rate is a better marker of symptomatic ischemic cerebrovascular events than velocity or diameter in severe carotid artery stenosis. J Vasc Surg. 2018. PMID: 29941314. doi:10.1016/j.jvs.2018.04.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。