不同支架移植物在喇叭口技术治疗腹主动脉瘤合并髂动脉瘤中的疗效比较研究
该回顾性研究分析了2011年1月至2016年12月在本机构使用喇叭口技术(BBT)保留髂内动脉的腹主动脉瘤合并髂动脉瘤患者,比较Zenith、Excluder和Endurant三种支架移植物的中期疗效。共纳入125例患者141个髂动脉瘤,98例(78.4%)113个病变(80.4%)获得中位随访38个月。结果显示三组间髂动脉瘤破裂率存在差异(P=0.03),I型Ib内漏、瘤囊扩大和远端瘤颈扩张发生率无显著差异。
要点
- 三种支架移植物间髂动脉瘤破裂率存在差异(P=0.03),Zenith组为8.6%,Excluder组和Endurant组均为0.0%。
- I型Ib内漏总发生率为14.2%,瘤囊扩大为9.7%,远端瘤颈扩张为21.2%,三组间无显著差异。
- 共14例(10.7%)因BBT相关问题接受进一步治疗。
核心结论
- 在亚洲人群中,BBT仍是标准EVAR中保留髂内动脉的安全有效治疗选择,并发症率可接受。
- 三种不同支架移植物的髂动脉瘤破裂率存在差异。
- 数据首次揭示支架移植物类型影响最终临床结局,治疗AAA-IAA时应适当选择髂动脉延伸支架。
研究设计与样本
- 回顾性分析2011年1月至2016年12月在本机构接受BBT保留髂内动脉的AAA合并IAA患者。
- 术后3个月、6个月,之后每12个月随访。
- 比较Zenith、Excluder和Endurant三种支架移植物的结局。
- BBT相关终点包括I型Ib内漏、IAA瘤囊扩张、远端瘤颈扩张和随访期间破裂。
主要发现
- 共纳入125例患者141个IAA;98例(78.4%)113个病变(80.4%)获得中位随访38个月。
- I型Ib内漏发生率在Zenith组为22.9%、Excluder组为8.3%、Endurant组为11.9%、总患者为14.2%(P=0.19)。
- IAA瘤囊扩大发生率在Zenith组为17.1%、Excluder组为5.6%、Endurant组为7.1%、总患者为9.7%(P=0.20)。
- IAA破裂发生率在Zenith组为8.6%、Excluder组为0.0%、Endurant组为0.0%、总患者为2.7%(P=0.03)。
- IAA瘤颈扩张发生率在Zenith组为34.3%、Excluder组为13.9%、Endurant组为16.7%、总患者为21.2%(P=0.07)。
临床怎么用
- 作者认为,BBT仍是标准EVAR中保留髂内动脉的安全有效治疗选择,并发症率可接受。
- 作者建议,治疗AAA-IAA时应适当选择髂动脉延伸支架。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bell-bottom technique (BBT) is one method to preserve the internal iliac artery during endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) that extends to iliac artery. The data on the efficacy of this technique are still limited. We sought to evaluate the midterm efficacy of BBT by using different stent grafts in the treatment of AAA combined with iliac artery aneurysm (IAA). METHODS: From January 2011 to December 2016, AAA patients with IAA using BBT to preserve the internal iliac artery were retrospectively analyzed in our institution. Patients were followed up at 3, 6, and then every 12 months after surgery. The outcomes among 3 types of stent grafts (Zenith, Excluder, and Endurant) were compared. BBT-related end points including type Ib endoleak, IAA sac expansion, distal neck expansion, and rupture during follow-up were compared. Other events including perioperative death, any other types of endoleak, and corresponding management were also documented. RESULTS: A total of 125 patients with 141 IAAs were identified. Ninety-eight patients (78.4%) with 113 lesions (80.4%) received a median follow-up time of 38 months. The incidence of type Ib endoleak was 22.9%, 8.3%, 11.9%, and 14.2% (P = 0.19) in Zenith, Excluder, Endurant group, and total patients, respectively. The incidence of IAA sac enlargement was 17.1%, 5.6%, 7.1%, and 9.7% (P = 0.20). The incidence of IAA rupture was 8.6%, 0.0%, 0.0%, and 2.7% (P = 0.03). The incidence of IAA neck enlargement was 34.3%, 13.9%, 16.7%, and 21.2% (P = 0.07). Totally, 14 cases (10.7%) received further treatment for BBT-related issues. CONCLUSIONS: Although BBT remains a safe and effective treatment option to preserve internal iliac artery during standard EVAR with acceptable complication rates in Asians, different IAA rupture rates were found among 3 different stent grafts. Our data for the first time revealed that the type of stent grafts has influence on the final clinical outcome. Based on that, iliac extension should be selected appropriately while treating AAA-IAA.
引用
- Wang L, Liang S, Xu X, et al. A Comparative Study of the Efficacy by using Different Stent Grafts in Bell-Bottom Technique for the Treatment of Abdominal Aortic Aneurysm Concomitant with Iliac Artery Aneurysm. Ann Vasc Surg. 2018. PMID: 29885433. doi:10.1016/j.avsg.2018.05.030