破裂与非破裂腹主动脉瘤的几何学分析
本研究收集多机构38例破裂腹主动脉瘤(AAA)与215例择期修复(非破裂)AAA的CT数据,按年龄、性别和AAA直径用马氏距离进行1:1匹配后比较两组几何参数。结果显示破裂组纵横比和圆角半径均显著低于非破裂组,圆角半径的曲线下面积达0.933,最佳截断值0.347,敏感度0.97、特异度0.87。
要点
- 破裂AAA组纵横比为2.02±0.53,低于非破裂组的2.60±1.02(P=.002)。
- 破裂AAA组圆角半径为0.28±0.18,低于非破裂组的0.81±0.44(P<.001)。
- 圆角半径的曲线下面积为0.933,最佳截断值0.347,敏感度0.97、特异度0.87。
核心结论
- 破裂AAA的圆角半径和纵横比均小于非破裂AAA。
研究设计与样本
- 从多个机构收集38例破裂AAA和215例择期修复(非破裂)AAA的CT数据,按年龄、性别和AAA直径用马氏距离进行1:1匹配后比较两组。
主要发现
- 破裂组纵横比为2.02±0.53,非破裂组为2.60±1.02,破裂组显著低于非破裂组(P=.002)。
- 破裂组圆角半径为0.28±0.18,非破裂组为0.81±0.44,破裂组显著低于非破裂组(P<.001)。
- 纵横比的曲线下面积为0.688,最佳截断值2.23,敏感度0.55、特异度0.76。
- 圆角半径的曲线下面积为0.933,最佳截断值0.347,敏感度0.97、特异度0.87。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to use parameters to determine the geometric differences between ruptured abdominal aortic aneurysms (AAAs) and nonruptured AAAs. METHODS: Computed tomography data of 38 ruptured AAAs and 215 electively repaired (nonruptured) AAAs were collected from multiple institutes. We compared the ruptured AAA group and nonruptured AAA group with 1:1 matching by using the Mahalanobis distance, which was calculated using the patient's age, sex, and AAA diameter. We selected the longitudinal AAA image in multiplanar reconstruction view, placed a hypothetical ellipse on the aneurysm's protruded curve, and placed a circle on the portion connecting the aneurysm and the aorta. We then measured the aspect ratio (the vertical diameter divided by the horizontal diameter) and fillet radius (the radius of arc). RESULTS: The aspect ratio was significantly lower in the ruptured group than in the nonruptured group (2.02 ± 0.53 vs 2.60 ± 1.02; P = .002), as was the fillet radius (0.28 ± 0.18 vs 0.81 ± 0.44; P < .001). Receiver operating characteristic analysis revealed that the area under the curve of the aspect ratio was 0.688, and the optimal cutoff point was 2.23, with sensitivity and specificity of 0.55 and 0.76, respectively. The area under the curve of the fillet radius was 0.933, and the optimal cutoff was 0.347, with sensitivity and specificity of 0.97 and 0.87, respectively. CONCLUSIONS: The geometric analysis performed in this study revealed that ruptured AAAs had a smaller fillet radius and smaller aspect ratio than nonruptured AAAs did.
引用
- Kimura M, Hoshina K, Miyahara K, et al. Geometric analysis of ruptured and nonruptured abdominal aortic aneurysms. J Vasc Surg. 2018. PMID: 29914827. doi:10.1016/j.jvs.2018.04.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。