钝性胸主动脉损伤短近端锚定区左锁骨下动脉保留的短期结果
单中心2006至2017年30例钝性胸主动脉损伤行胸主动脉腔内修复术,左锁骨下动脉保留23例、覆盖7例。保留组平均锚定区16 mm,覆盖组1.8 mm,手术成功率分别为96%和100%。作者认为短近端锚定区10至20 mm及部分5至10 mm患者保留左锁骨下动脉行胸主动脉腔内修复术似乎安全有效。
要点
- 钝性胸主动脉损伤行胸主动脉腔内修复术时,保留左锁骨下动脉的短近端锚定区(10至20 mm及部分5至10 mm)似乎安全有效。
- 30例中左锁骨下动脉保留23例、覆盖7例,保留组平均锚定区16 mm,覆盖组1.8 mm。
- 随访影像仅1例残余内漏,存活患者25例中5例无术后影像,其中2例死于非主动脉相关原因。
核心结论
- 对近端锚定区10至20 mm及部分5至10 mm的钝性胸主动脉损伤患者,胸主动脉腔内修复术似乎安全有效。
- 胸主动脉腔内修复术后主动脉未见残余损伤,移植物可能更多作为促进愈合的桥接。
- 左锁骨下动脉覆盖的长期问题因该人群随访 historically 较差而难以确定和评估。
- 保留锁骨下动脉即使近端锚定区较短,也可能避免左锁骨下动脉覆盖和血运重建的潜在问题。
研究设计与样本
- 单中心2006年至2017年钝性胸主动脉损伤行胸主动脉腔内修复术的经验。
- 共30例胸主动脉腔内修复术,患者平均年龄38.7岁(标准差19.8岁),70%为男性。
- 平均损伤严重程度评分为36.75(标准差13.1)。
- 治疗患者为2级(36.7%)或3级(63.3%)钝性胸主动脉损伤。
主要发现
- 左锁骨下动脉保留23例,覆盖7例。
- 左锁骨下动脉未覆盖组平均锚定区为16 mm(标准差10.4 mm),其中15例(65%)锚定区<20 mm,8例(35%)锚定区>20 mm。
- 7例覆盖组平均锚定区为1.8 mm(标准差2.4 mm)。
- 手术成功率未覆盖组为96%,覆盖组为100%。
- 随访影像中,所有存活患者(n=25)仅1例残余内漏;5例无术后影像,其中2例(7%)死于非主动脉相关原因。
临床怎么用
- 作者认为,对近端锚定区10至20 mm及部分5至10 mm的钝性胸主动脉损伤患者,保留左锁骨下动脉行胸主动脉腔内修复术似乎安全有效。
- 作者认为,保留锁骨下动脉即使近端锚定区较短,也可能避免左锁骨下动脉覆盖和血运重建的潜在问题。
局限性
- 左锁骨下动脉覆盖的长期问题因该人群随访 historically 较差而难以确定和评估。
- 5例患者无术后影像,其中2例(7%)死于非主动脉相关原因。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is the standard treatment of blunt thoracic aortic injury (BTAI). The concept of seal was derived from the treatment of aneurysms and has been adopted for BTAI. Given the location of injury in BTAI, left subclavian artery (LSA) coverage is sometimes necessary. In these often healthier aortas, a shorter proximal landing zone may be acceptable and beneficial in avoiding some complications. Current practice patterns vary, and long-term effects of LSA coverage remain unknown. METHODS: A single-institution experience with BTAI for TEVAR was examined from 2006 to 2017. The primary outcome was failure of sealing, endoleak, or persistent aortic injury on follow-up imaging. A centerline was used to measure the length of the landing zone, aortic diameter, and other parameters. Post-TEVAR computed tomography scans were examined for evidence of residual aortic injury. RESULTS: A total of 30 TEVARs were performed for BTAI. The mean age of the patients was 38.7 years (standard deviation [SD], 19.8 years), and 70% were male. The mean injury severity score was 36.75 (SD, 13.1). Treated patients had grade 2 (36.7%) or grade 3 (63.3%) BTAI. The LSA was salvaged in 23 cases and covered in seven cases. The mean landing zone in LSA uncovered cases was 16 mm (SD, 10.4 mm). There were 15 patients (65%) who had a landing zone <20 mm, and eight (35%) patients had a landing zone >20 mm. The mean landing zone in the seven covered cases was 1.8 mm (SD, 2.4 mm). Procedural success was 96% for the uncovered group and 100% for the covered group. On follow-up imaging, there was only one residual endoleak in all surviving patients (n = 25). Five patients did not have postoperative imaging, two (7%) of whom died of nonaorta-related issues. CONCLUSIONS: TEVAR for BTAI in patients with short proximal landing zones of 10 to 20 mm as well as in select patients with landing zones of 5 to 10 mm appears to be safe and efficacious. The aorta demonstrates no residual injury after TEVAR, with the graft acting potentially more as a bridge to allow healing. Long-term issues regarding LSA coverage have been difficult to ascertain and to evaluate because of historically poor follow-up in this population of patients. However, potential issues with LSA coverage and revascularization may be avoided by preserving the subclavian artery even with shorter proximal landing zones.
引用
- Skripochnik E, Novikov D, Bilfinger TJ, et al. Short-term results of left subclavian artery salvage in blunt thoracic aortic injury with short proximal landing zones. J Vasc Surg. 2018. PMID: 29784567. doi:10.1016/j.jvs.2018.01.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。