编辑推荐——近端主动脉瘤颈直径对血管腔内动脉瘤修复术后瘤囊封闭持久性与总生存的影响:来自Gore全球血管腔内主动脉治疗登记(GREAT)的真实世界数据
基于GREAT登记中2011至2017年78个中心3166例接受Gore Excluder支架行肾下腹主动脉瘤腔内修复的连续患者,按近端瘤颈直径<25 mm(NAN组1977例)与≥25 mm(LAN组1189例)分组。LAN组5年免于IA型内漏率更低(96.8% vs 98.6%,p=.007),5年生存率更低(64.6% vs 76.5%,p=.03)。结论认为LAN与迟发IA型内漏及较低总生存相关。
要点
- 近端瘤颈≥25 mm(LAN)组5年免于IA型内漏率为96.8%,低于NAN组的98.6%(p=.007)。
- LAN组5年生存率为64.6%,低于NAN组的76.5%(p=.03)。
- 免于主动脉再干预率两组差异未达统计学显著(LAN 78.6% vs NAN 86.0%,p=.11)。
核心结论
- 大近端主动脉瘤颈(LAN)与迟发IA型内漏发生及较低总生存相关。
研究设计与样本
- 研究为基于GREAT登记前瞻性收集个体患者数据的分析,纳入2011至2017年78个全球中心3166例接受Gore Excluder支架行肾下腹主动脉瘤腔内修复的连续患者。
- 按基线近端主动脉瘤颈直径将患者分为NAN组(CT主动脉造影<25 mm,1977例,62.4%)与LAN组(≥25 mm,1189例,37.6%)。
- 干预后5年76.5%的患者可获得临床随访(包括影像学)。
主要发现
- 即刻技术成功3164/3166例(>99.9%)。
- 总体免于IA型内漏率1年为99.3%、5年为97.3%;5年时LAN组96.8%(CI 93.7-98.4)低于NAN组98.6%(CI 94.5-99.6),p=.007。
- 总体免于主动脉再干预率1年为93.7%、5年为83.2%;5年时LAN组78.6%(CI 66.0-87.0) vs NAN组86.0%(CI 81.8-89.3),p=.11。
- 总体免于主要复合终点率1年为95.9%、5年为84.9%;5年时LAN组81.3%(CI 69.2-89.0) vs NAN组87.0%(CI 81.6-91.0),p=.066。
- 5年生存率LAN组64.6%(CI 50.1-75.7)低于NAN组76.5%(CI 70.7-81.3),p=.03。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Aortic neck diameter is an independent anatomical feature that is poorly understood, yet potentially linked to proximal seal failure and adverse outcome following standard EVAR. The aim of this study was to assess whether large proximal aortic neck (LAN) diameter is associated with adverse outcome using prospectively collected individual patient data from The Global Registry for Endovascular Aortic Treatment (GREAT). METHODS: A total of 3166 consecutive patients, from 78 global centres, receiving Gore Excluder stent grafts for infrarenal abdominal aortic aneurysm repair between 2011 and 2017 were included. Patient demographics, biometrics, operative details, and clinical outcome were analysed. Patients were divided into two groups: normal baseline proximal aortic neck (NAN) diameter (<25 mm on computed tomography aortography), and LAN (≥25 mm). Clinical follow up (including imaging) was available for 76.5% of patients 5 years post-intervention. Primary endpoints analysed were Type IA endoleak and any aortic re-intervention up to 5 years post-procedure. A composite endpoint of Type IA endoleak, re-intervention, aortic rupture, or aortic related mortality was also assessed. RESULTS: A total of 1977 (62.4%) patients were classified NAN and 1189 (37.6%) were LAN. Immediate technical success was achieved in 3164 out of 3166 (>99.9%) of cases. Freedom from Type IA endoleak was achieved in 99.3% at 1 year and 97.3% at 5 years (lower in LAN vs. NAN: 96.8% [CI 93.7-98.4] vs. 98.6% [CI 94.5-99.6], p = .007). Freedom from aortic re-intervention was 93.7% at 1 year and 83.2% at 5 years (78.6% [CI 66.0-87.0] LAN vs. 86.0% [CI 81.8-89.3] NAN, p = .11). Freedom from primary composite endpoint was 95.9% at 1 year and 84.9% at 5 years (81.3% [CI 69.2-89.0] LAN vs. 87.0% [CI 81.6-91.0] NAN, p = .066). Five year survival was lower in the LAN group; 64.6% (CI 50.1-75.7) vs. 76.5% (CI 70.7-81.3), p = .03). CONCLUSION: LAN is associated with delayed Type IA endoleak occurrence and lower overall survival.
引用
- Howard DPJ, Marron CD, Sideso E, et al. Editor's Choice - Influence of Proximal Aortic Neck Diameter on Durability of Aneurysm Sealing and Overall Survival in Patients Undergoing Endovascular Aneurysm Repair. Real World Data from the Gore Global Registry for Endovascular Aortic Treatment (GREAT). Eur J Vasc Endovasc Surg. 2018. PMID: 29764709. doi:10.1016/j.ejvs.2018.03.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。