腹主动脉瘤腔内修复术后随访不依从的预测因素
该研究回顾了1995年至2015年间在悉尼2家医院连续接受腹主动脉瘤腔内修复术(EVAR)的1482例患者,其中338例(22.8%)未遵循标准随访。不依从者更年轻、合并高血压、当前吸烟、非英语背景比例更高(28.4% vs 17.9%,P=0.01),且居住地距治疗中心更近(109±151.5 km vs 150±208.34 km,P=0.01)。作者认为当前吸烟和非英语背景与随访不依从相关,是潜在的干预领域。
要点
- EVAR术后随访不依从率为22.8%(338/1482例)。
- 不依从者中非英语背景比例为28.4%,依从者为17.9%(P=0.01)。
- 不依从者距治疗中心距离为109±151.5 km,依从者为150±208.34 km(P=0.01)。
核心结论
- EVAR术后随访仍不理想,当前吸烟和非英语背景与随访不依从相关,是潜在的干预领域。
研究设计与样本
- 回顾性研究,纳入1995年至2015年间在悉尼2家医院连续接受EVAR的1482例患者,将不依从随访者与依从对照组比较。
主要发现
- 1482例接受EVAR的患者中,338例(22.8%)随访不依从。
- 不依从者显著更年轻、合并高血压、当前吸烟。
- 不依从者中非英语背景比例为28.4%,依从者为17.9%(P=0.01)。
- 不依从者距治疗中心距离为109±151.5 km,依从者为150±208.34 km(P=0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although the potential for complications after endovascular aneurysm repair (EVAR) mandates lifetime follow-up, noncompliance with follow-up has been shown to be as high as 57%. We sought to investigate the incidence of noncompliance with follow-up in our patient population and to identify risk factors associated with this to allow implementation of targeted strategies to prevent loss to follow-up. METHODS: We carried out a review of consecutive patients undergoing EVAR at 2 Sydney hospitals between 1995 and 2015. Patients noncompliant with standard follow-up were compared with a control group of compliant patients. Data collected included baseline clinical characteristics, perioperative complications, and postoperative complications, as well as distance from treating centers. RESULTS: During the study period, 1,482 patients underwent EVAR, of which 338 patients (22.8%) were not compliant with follow-up. Patients noncompliant with follow-up were significantly more likely to be younger, have hypertension, and be current smokers. Patients who did not attend follow-up were also significantly more likely to be from a non-English-speaking background (28.4 vs. 17.9%; P = 0.01) and live closer to the treating institution (109 ± 151.5 vs. 150 ± 208.34 km; P = 0.01). CONCLUSIONS: Follow-up after EVAR remains suboptimal. The present study serves to demonstrate that several factors, especially current smoking and a non-English-speaking background, are associated with poor compliance with follow-up after EVAR in our patient population and represent a potential area of intervention to improve compliance.
引用
- Shiraev TP, Durur E, Robinson DA, et al. Factors Predicting Noncompliance with Follow-up after Endovascular Aneurysm Repair. Ann Vasc Surg. 2018. PMID: 29793019. doi:10.1016/j.avsg.2018.03.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。