当前主动脉腔内移植物激光原位开窗的实验研究
体外研究比较激光原位开窗(LISF)与机械原位开窗(MISF)对五种主动脉腔内移植物织物(32个样本)的损伤,LISF后拉伸强度损失34%(p=.004),MISF损失27%(p=.001),LISF较MISF总机械阻力降低7%但无显著差异(p=.520)。多丝样本LISF渗漏率高于MISF(p<.05)。绵羊体内研究12只绵羊完成14例LISF,技术成功率88%。结论认为两者均造成显著损伤,在未经加强开窗对比前不应在研究外使用。
要点
- LISF后织物拉伸强度损失34%(p=.004),MISF损失27%(p=.001)。
- 多丝样本LISF渗漏率高于MISF(p<.05),单丝样本未见差异。
- 12只绵羊完成14例LISF,技术成功率88%。
核心结论
- LISF和MISF均对现有腔内移植物织物造成显著损伤,在完成与加强开窗的对比前,两者不应在研究之外使用。
研究设计与样本
- 体外研究使用五种市售主动脉腔内移植物的32个聚对苯二甲酸乙二醇酯和膨体聚四氟乙烯织物样本,比较LISF与针头MISF的损伤。
- 体外评估包括开窗前后的拉伸强度测试、支架-开窗界面的整体水渗透性测试以及弯曲分支的疲劳台架测试。
- 第二步进行绵羊体内LISF研究。
主要发现
- LISF后孔洞边缘呈圆形且烧灼状,MISF后织物纤维被推向一旁。
- 与非开窗样本相比,LISF后机械阻力损失34%(p=.004),MISF后损失27%(p=.001)。
- LISF较MISF总机械阻力降低7%,但无统计学显著差异(p=.520)。
- 多丝样本中LISF渗漏率高于MISF(p<.05)。
- 疲劳测试170,000次循环后所有样本开窗表面积增加;体内研究12只绵羊完成14例LISF,技术成功率88%。
临床怎么用
- 作者认为,在完成与加强开窗的对比之前,LISF和MISF不应在研究之外使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE/BACKGROUND: Laser in situ fenestration (LISF) is emerging as an immediately available alternative in the endovascular treatment of complex aortic aneurysm. However, its biomechanical features remain poorly understood. The aim of this study was to experimentally evaluate textile damage secondary to LISF and to compare LISF with mechanical in situ fenestration (MISF). METHODS: An in vitro study evaluated the damage created by LISF on endograft fabrics versus MISF using a needle. Five different models of commercially available aortic endografts were used (32 samples of polyethylene terephthalate and expanded polytetrafluoroethylene fabrics). Tensile strength tests were performed on the fabrics before and after in situ fenestration, to determine the loss of mechanical strength. Integral water permeability tests at the stent-fenestration interface evaluated the watertightness of junctions. Stability of the connection was assessed with a fatigue bench test flexing the branch on the fenestration. In a second step, an in vivo study evaluating LISF in sheep was conducted. RESULTS: Resulting holes had circular and cauterised edges following LISF, whereas fabric filaments were pushed aside after MISF. Tensile tests demonstrated a 34% and a 27% mechanical resistance loss after LISF (p = .004) and MISF (p = .001) compared with non-fenestrated samples. A non-significant global decrease of 7% in mechanical resistance was found following LISF compared with MISF (p = .520). Water permeability tests highlighted that leak rates were higher following LISF than with MISF with regard to multifilament specimens (p < .05). Fatigue tests induced modification of the morphology of fenestrations. The surface area of the fenestration was increased for all samples after 170,000 cycles. Regarding the in vivo study, 14 LISF were performed in 12 sheep with a technical success rate of 88%. CONCLUSION: This study demonstrates that both LISF and MISF create substantial damage to all available endograft fabrics. Until comparisons with reinforced fenestrations are performed, LISF and MISF should not be used outside investigational studies.
引用
- Jayet J, Heim F, Coggia M, et al. An Experimental Study of Laser in situ Fenestration of Current Aortic Endografts. Eur J Vasc Endovasc Surg. 2018. PMID: 29706260. doi:10.1016/j.ejvs.2018.03.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。