因近端主动脉瘤颈失败而取出Nellix血管内主动脉密封内假体
本文报告2例因装置移位并继发IA型内漏而需取出Nellix内假体的病例,描述了开放转换的技术与细节。既往报告的Nellix取出均因移植物感染,而因近端主动脉瘤颈失败行开放转换的病例罕见讨论。
要点
- Nellix内假体通过瘤囊内聚合物填充实现血管内动脉瘤密封,与其他装置不同。
- 本文报告2例因装置移位继发IA型内漏而取出Nellix内假体的病例。
- 既往报告的Nellix取出均因移植物感染,近端瘤颈失败取出的技术细节见本文。
核心结论
- 本文描述了因近端主动脉瘤颈失败而开放转换取出Nellix内假体的技术和观察到的细节。
研究设计与样本
- 本文为病例报告,报告2例Nellix内假体取出病例。
主要发现
- 2例Nellix内假体取出均因装置移位并继发IA型内漏。
- 既往报告的Nellix取出均因移植物感染。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Open conversion after endovascular aortic repair has inherent challenges particular to the device being explanted. The Nellix endograft is unlike any other device as it uses polymer filling of endobags within the aorto-iliac lumen to seal the abdominal aortic aneurysm (AAA) sac, a developing concept known as endovascular aneurysm sealing. Conversion to open repair of AAA treated with the Nellix endograft has rarely been discussed. Explants that have been previously reported were for graft infection. We present 2 Nellix graft explants that were required for device migration and subsequent development of a type IA endoleak. The technique and nuances observed during open conversion of this novel endograft for proximal aortic neck failure is described in this report.
引用
- Lee CJ, Cuff R. Explanting the Nellix Endovascular Aortic Sealing Endoprosthesis for Proximal Aortic Neck Failure. Ann Vasc Surg. 2018. PMID: 29778615. doi:10.1016/j.avsg.2018.02.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。