超声引导下腔静脉滤器置入的新方法
本研究纳入2010年10月22日至2016年6月30日存在肺栓塞高风险或已发生肺栓塞的患者,介绍一种经腹部超声引导下腔静脉滤器置入的新方法。共评估1029例,排除98例(9.5%),931例(90.5%)接受置入,所有滤器(100%)成功置入,无操作相关并发症。作者认为该方法简单、安全、有效,或可广泛用于床旁滤器置入。
要点
- 共评估1029例,98例(9.5%)因下腔静脉显示不清、血栓或解剖不合适被排除。
- 931例(90.5%)接受经腹部超声引导置入,所有滤器(100%)成功置入,无操作相关并发症。
- CT见4例(0.4%)滤器位于肾上段,平片见15例(1.6%)滤器尖端超过L2上缘。
核心结论
- 作者认为这种经腹部超声引导下腔静脉滤器置入的新方法简单、安全、有效,或可广泛用于床旁腔静脉滤器置入。
研究设计与样本
- 研究纳入2010年10月22日至2016年6月30日存在肺栓塞高风险或已发生肺栓塞的患者,介绍并评估经腹部超声引导下腔静脉滤器置入的新方法。
主要发现
- 共评估1029例患者,98例(9.5%)被排除,其中下腔静脉显示不清14例(1.4%)、下腔静脉或双侧髂静脉血栓79例(7.7%)、解剖不合适5例(0.5%)。
- 剩余931例(90.5%)接受经腹部超声引导下腔静脉滤器置入,所有滤器(100%)成功置入。
- 无操作相关并发症。
- CT观察到4例(0.4%)滤器位于肾上段,平片观察到15例(1.6%)滤器尖端超过L2上缘,其中1例有两个右肾静脉。
- 1例发生严重滤器倾斜(20.8度)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Transabdominal ultrasound (TAUS)-guided inferior vena cava filter (IVCF) placement currently uses an inferior vena cava (IVC) longitudinal plane with cross-section of the right renal artery or the transverse plane of the right renal vein (RRV)-IVC intersection. The goal of this study was to introduce a new method for TAUS-guided IVCF placement. METHODS: The study enrolled patients who were at high risk for or had pulmonary embolism from October 22, 2010, to June 30, 2016. The probe was positioned on the right flank to centralize the RRV-IVC junction during imaging and to permit a straight line through the midpoint of the probe on the surface and a parallel line 1.0 cm below the straight line as a marker. The probe was subsequently placed on the abdominal wall with the upper edge at the marker line to show the long axis of the IVC during the process of filter placement. The upper edge of the probe was considered the filter tip position. RESULTS: A total of 1029 patients were evaluated, and 98 patients (9.5%) were excluded because of poor IVC visualization (n = 14 [1.4%]), IVC or bilateral iliac vein thrombosis (n = 79 [7.7%]), and unsuitable anatomy (n = 5 [0.5%]). The remaining 931 patients (90.5%) were selected for TAUS-guided IVCF placement, and all filters (100%) were successfully placed. There were no procedure-related complications. Suprarenal IVCF was observed in 4 patients (0.4%) by computed tomography, and the filter tip exceeded the upper edge of L2 in 15 patients (1.6%) by plain film radiography; one of them had two RRVs. Severe filter tilting (20.8 degrees) occurred in one patient. CONCLUSIONS: This new method of TAUS-guided IVCF placement was simple, safe, and effective. It may be widely applied for the bedside placement of vena cava filters.
引用
- Qin X, Lu C, Ren P, et al. New method for ultrasound-guided inferior vena cava filter placement. J Vasc Surg Venous Lymphat Disord. 2018. PMID: 29602758. doi:10.1016/j.jvsv.2017.12.057
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。