慢性DeBakey IIIB型夹层患者胸主动脉腔内修复术中假腔处理的效果
本研究回顾2012至2016年73例因慢性DeBakey IIIB型夹层行胸主动脉腔内修复术(TEVAR)的患者,其中41例联合假腔处理(FLP,A组),32例仅行TEVAR(B组)。A组全胸主动脉假腔血栓化率显著高于B组(83% vs 56%;P = .002),两组均观察到主动脉重塑。多变量Cox回归显示FLP和再破口数量是胸段假腔血栓化的独立预测因素。
要点
- 联合假腔处理的TEVAR组全胸主动脉假腔血栓化率显著高于单纯TEVAR组(83% vs 56%;P = .002)。
- 多变量Cox回归中,FLP为胸段假腔血栓化的独立预测因素(HR 2.339;P = .009)。
- 再破口数量为胸段假腔血栓化的独立预测因素(HR 0.709;P < .001)。
核心结论
- 全覆膜TEVAR联合假腔处理似乎是安全的血管内治疗方法,并促进慢性DeBakey IIIB型夹层患者的胸段假腔血栓化。
研究设计与样本
- 回顾性分析2012至2016年73例因慢性DeBakey IIIB型夹层行TEVAR的患者,A组41例(56%)联合假腔处理,B组32例(44%)仅行TEVAR。
主要发现
- 无院内死亡,术后各有1例截瘫和卒中。
- 全胸主动脉假腔血栓化率A组83% vs B组56%(P = .002)。
- 两组均观察到显著的主动脉重塑(真腔扩张和假腔回缩)。
- 多变量Cox回归中,FLP为胸段假腔血栓化的独立预测因素(HR 2.339;P = .009),再破口数量为独立预测因素(HR 0.709;P < .001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Although thoracic endovascular aortic repair (TEVAR) is commonly used for chronic DeBakey type IIIB (CDIIIB) dissections, aortic remodeling outcomes after the procedure have been unsatisfactory. Persistent retrograde flow to the false lumen (FL) through re-entry tears commonly causes treatment failure. The aim of this study was to clarify the safety and effect of the FL procedure (FLP) for aortic remodeling in patients with CDIIIB dissections. METHODS: From 2012 to 2016, there were 73 patients who underwent TEVAR for CDIIIB dissections. The surgery, accompanied by the FLP, was performed in 41 patients (group A, 56%); 32 patients (group B, 44%) underwent TEVAR alone. The FLP was defined as blocking the retrograde FL flow with commercial materials. Outcomes included whole thoracic aorta FL thrombosis and diameter change in the true lumen and FL. Diameters were measured at three levels (left subclavian artery, pulmonary artery bifurcation, and celiac axis). RESULTS: No in-hospital mortality was observed. There was one case each of paraplegia and stroke postoperatively. The whole thoracic aorta FL thrombosis rate was significantly higher in group A (83% vs 56%; P = .002). Significant aortic remodeling (true lumen expansion and FL regression) was observed in both groups. In multivariable Cox regression analysis, the FLP and the number of re-entries were independent predictors for thoracic FL thrombosis (hazard ratio, 2.339 [P = .009] and 0.709 [P < .001], respectively). CONCLUSIONS: Full-coverage TEVAR with the FLP seems to be a safe endovascular treatment and promotes thoracic FL thrombosis for patients with CDIIIB dissections.
引用
- Kim TH, Song SW, Lee KH, et al. The effect of false lumen procedures during thoracic endovascular aortic repair in patients with chronic DeBakey type IIIB dissections. J Vasc Surg. 2018. PMID: 29685514. doi:10.1016/j.jvs.2018.01.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。