循环血管基底膜碎片与腹主动脉直径相关且其表达模式在腹主动脉瘤组织中改变
这项回顾性人群队列研究在615名男性中按主动脉直径分组,用ELISA检测血浆IV型胶原和XVIII型胶原/内皮抑素水平,发现两者均与较大的主动脉直径相关,XVIII型/内皮抑素基线水平与扩张速率相关,但多变量模型中仅初始主动脉直径与扩张显著相关,免疫荧光显示腹主动脉瘤组织中两种胶原表达模式改变。
要点
- 血浆XVIII型胶原/内皮抑素水平随主动脉直径增大而升高(正常主动脉136 ng/mL vs 腹主动脉瘤162 ng/mL,p=.001)。
- 血浆IV型胶原水平随主动脉直径增大而升高(正常主动脉105 ng/mL vs 腹主动脉瘤127 ng/mL,p=.037)。
- 多变量模型中仅初始主动脉直径与扩张速率显著相关(p=.005)。
核心结论
- 循环IV型和XVIII型胶原/内皮抑素血浆水平随腹主动脉瘤直径增大而升高,血管基底膜蛋白在动脉瘤壁中的表达模式发生改变。
研究设计与样本
- 回顾性人群队列研究,纳入615名男性,按主动脉直径分为正常主动脉≤25 mm、亚动脉瘤主动脉26-29 mm和腹主动脉瘤≥30 mm三组。
- 159名男性有随访数据,采用序贯 logistic 回归和线性回归模型分析胶原水平与基线主动脉直径及随访扩张速率的关联,并控制常见混杂因素。
- 免疫荧光分析正常主动脉(n=6)和腹主动脉瘤(n=6)组织中胶原的组织表达。
主要发现
- 血浆XVIII型胶原/内皮抑素水平:正常主动脉直径组136 ng/mL(SD 29),亚动脉瘤主动脉组154 ng/mL(SD 45),腹主动脉瘤组162 ng/mL(SD 46),p=.001。
- 血浆IV型胶原水平:正常主动脉组105 ng/mL(SD 42),亚动脉瘤主动脉组124 ng/mL(SD 46),腹主动脉瘤组127 ng/mL(SD 47),p=.037。
- XVIII型/内皮抑素基线水平与主动脉扩张速率存在显著关联(p=.035),但多变量模型中仅初始主动脉直径与扩张显著相关(p=.005)。
- 免疫荧光观察到腹主动脉瘤组织中两种胶原的表达模式改变。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Abdominal aortic aneurysm (AAA) is characterised by enhanced proteolytic activity, and extracellular matrix (ECM) remodelling in the vascular wall. Type IV and XVIII collagen/endostatin are structural proteins in vascular basement membrane (VBM), a specialised ECM structure. Here the association between plasma levels of these collagens with the aortic diameter and expansion rate is studied, and their expression in aortic tissue characterised. METHODS: This was a retrospective population based cohort study. Type IV and XVIII collagen/endostatin were analysed in plasma by ELISA assay in 615 men, divided into three groups based on the aortic diameter: 1) normal aorta ≤ 25 mm, 2) sub-aneurysmal aorta (SAA) 26-29 mm, and 3) AAA ≥ 30 mm. Follow up data were available for 159 men. The association between collagen levels and aortic diameter at baseline, and with the expansion rate at follow up were analysed in ordinal logistic regression and linear regression models, controlling for common confounding factors. Tissue expression of the collagens was analysed in normal aorta (n = 6) and AAA (n = 6) by immunofluorescence. RESULTS: Plasma levels of type XVIII collagen/endostatin (136 ng/mL [SD 29] in individuals with a normal aorta diameter, 154 ng/ml [SD 45] in SAA, and 162 ng/ml [SD 46] in AAA; p = .001) and type IV collagen (105 ng/mL [SD 42] normal aorta, 124 ng/ml [SD 46] SAA, and 127 ng/ml [SD 47] AAA; p = .037) were associated with a larger aortic diameter. A significant association was found between the baseline levels of type XVIII/endostatin and the aortic expansion rate (p = .035), but in the multivariable model, only the initial aortic diameter remained significantly associated with expansion (p = .005). Altered expression patterns of both collagens were observed in AAA tissue. CONCLUSION: Plasma levels of circulating type IV and XVIII collagen/endostatin increase with AAA diameter. The expression pattern of VBM proteins is altered in the aneurysm wall.
引用
- Holsti M, Wanhainen A, Lundin C, et al. Circulating Vascular Basement Membrane Fragments are Associated with the Diameter of the Abdominal Aorta and Their Expression Pattern is Altered in AAA Tissue. Eur J Vasc Endovasc Surg. 2018. PMID: 29656960. doi:10.1016/j.ejvs.2018.03.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。