文献速递主动脉疾病

主动脉颈部特征对血管腔内动脉瘤修复术中EndoAnchor成功穿透主动脉壁的影响

Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair.
PubMed 文献 · J Vasc Surg · 2018-01-01

本研究纳入ANCHOR注册研究中86例因IA型内漏使用EndoAnchor的患者,术后首次CT显示53例无内漏、33例持续内漏。无内漏组良好穿透的EndoAnchor中位数显著更多(4 vs 3,P=.002)。主动脉颈部直径较大或钙化较厚时穿透较差,无穿透是术后IA型内漏的唯一预测因素。

要点

  • 无内漏组良好穿透的EndoAnchor中位数4枚,显著多于内漏组的3枚(P=.002)。
  • 使用Medtronic Endurant内移植物与良好穿透相关(P=.001)。
  • 肾动脉下10 mm处主动脉颈部直径较大(P<.001)及近端颈部钙化较厚(P=.004)与穿透不良相关。

核心结论

  • 当主动脉颈部直径较大或颈部存在显著附壁钙化时,EndoAnchor充分穿透主动脉壁的可能性较低。
  • EndoAnchor无穿透是术后IA型内漏的唯一预测因素。
  • 本研究强调基于CT血管造影对肾下颈部进行术前评估以仔细选择患者的重要性,并强调将EndoAnchor仔细部署入主动脉壁以改善IA型内漏的成功治疗。

研究设计与样本

  • ANCHOR注册研究(使用Heli-FX主动脉固定系统治疗动脉瘤的全球注册研究)的子集分析。
  • 纳入标准为EndoAnchor使用指征为治疗IA型内漏且术后增强CT质量足以供核心实验室审阅的患者。
  • 排除在EndoAnchor植入过程中植入cuff或支架的患者。
  • 共纳入86例患者,来自主要组61例(71%)和翻修组25例(29%)。

主要发现

  • 术后首次CT显示53例(62%)无持续IA型内漏,33例(38%)有持续IA型内漏。
  • 无内漏组良好穿透的EndoAnchor中位数为4枚(四分位距3-5),内漏组为3枚(四分位距1.5-4),差异显著(P=.002)。
  • 多因素模型显示使用Medtronic Endurant内移植物与良好穿透相关(P=.001)。
  • 穿透不良与肾动脉最低处远端10 mm处主动脉颈部直径较大(P<.001)及近端颈部钙化厚度较大(P=.004)相关。
  • 在IA型内漏成功治疗的多因素模型中,EndoAnchor穿透是唯一达到显著的变量(P<.001)。

关键数值与推荐

  • 良好穿透定义为EndoAnchor穿透主动脉壁≥2 mm。
  • 边缘穿透定义为EndoAnchor穿透<2 mm或内移植物与主动脉壁之间存在间隙。
  • 无穿透定义为EndoAnchor未穿透主动脉壁。
  • 手术成功定义为无IA型内漏。

临床怎么用

  • 作者强调基于CT血管造影对肾下颈部进行术前评估以仔细选择患者的重要性。
  • 作者强调将EndoAnchor仔细部署入主动脉壁以改善IA型内漏的成功治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study sought to quantify EndoAnchor (Medtronic Vascular, Santa Rosa, Calif) penetration into the aortic wall in patients undergoing endovascular abdominal aortic aneurysm repair and to assess predictors of successful penetration and its relationship to postprocedural type IA endoleak. METHODS: A subset of patients from the Aneurysm Treatment Using the Heli-FX Aortic Securement System Global Registry (ANCHOR) were included if they met the following criteria: the indication for EndoAnchor use was to treat a type IA endoleak, and postprocedure contrast-enhanced computed tomography (CT) scans of sufficient quality were available for core laboratory review. Patients undergoing implantation of cuffs or stents during the EndoAnchor implantation procedure were excluded. Baseline anatomic characteristics were recorded. The cohort was divided into patients with and without persistent type IA endoleaks at the first postoperative CT scan. Penetration of each EndoAnchor measured on this CT scan was defined as good penetration when the EndoAnchor penetrated ≥2 mm into the aortic wall, borderline penetration when EndoAnchor penetration was <2 mm or a gap remained between the endograft and aortic wall, or no penetration when the EndoAnchor did not penetrate into the aortic wall. Differences between the groups were analyzed with the Mann-Whitney U test or Fisher exact test. Multivariate analyses were performed to identify independent predictors of EndoAnchor penetration, and procedural success was defined by absence of type IA endoleak. RESULTS: Eighty-six patients of the primary (n = 61 [71%]) and revision (n = 25 [29%]) arms of the ANCHOR registry were included. There were 53 (62%) without and 33 (38%) with persistent type IA endoleaks on the first postprocedural CT scan. The median number of EndoAnchors with good penetration was significantly greater in the cohort without endoleaks, 4 (interquartile range, 3-5) vs 3 (interquartile range, 1.5-4), respectively (P = .002). A multivariate model for EndoAnchor penetration identified use of a Medtronic Endurant endograft as a factor associated with good penetration (P = .001), whereas poor penetration was associated with a larger aortic neck diameter 10 mm distal to the lowest renal artery (P < .001) and greater proximal neck calcium thickness (P = .004). EndoAnchor penetration was the only variable that attained significance (P < .001) in the multivariate model for successful treatment of a type IA endoleak. CONCLUSIONS: Adequate EndoAnchor penetration into the aortic wall is less likely when the aortic neck diameter is large or when the neck contains significant mural calcium. No penetration of the EndoAnchor was the only factor predictive of postprocedural type IA endoleak. This study stresses the importance of careful selection of patients based on preoperative assessment of the infrarenal neck on CT angiography and emphasizes careful deployment of EndoAnchors into the aortic wall to improve successful treatment of type IA endoleaks.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Goudeketting SR, van Noort K, Ouriel K, et al. Influence of aortic neck characteristics on successful aortic wall penetration of EndoAnchors in therapeutic use during endovascular aneurysm repair. J Vasc Surg. 2018. PMID: 29691099. doi:10.1016/j.jvs.2018.01.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。