三维融合成像与多模态路径图系统在主动脉腔内修复术中应用的可行性
回顾性分析263例择期腹主动脉腔内修复(EVAR)和胸主动脉腔内修复(TEVAR)病例,比较使用与未使用多模态路径图(MMR)系统的结果。MMR+组EVAR和TEVAR的对比剂用量均显著低于MMR-组,TEVAR的辐射暴露和手术时间也显著降低,入路损伤及其他并发症发生率相似。
要点
- MMR+组EVAR对比剂用量显著低于MMR-组(28.2±10.2 g vs 32.9±10.6 g,P=.009)。
- MMR+组TEVAR对比剂用量、辐射剂量和手术时间均显著低于MMR-组。
- 两组入路损伤及其他并发症发生率相似。
核心结论
- 三维融合成像的MMR系统可降低EVAR的对比剂剂量,并降低TEVAR的对比剂暴露和辐射暴露。
研究设计与样本
- 回顾性分析263例连续择期EVAR和TEVAR病例,MMR系统应用于164例(62.4%)。
- MMR-组包括62例EVAR和37例TEVAR,MMR+组包括81例EVAR和83例TEVAR。
- 在EVAR和TEVAR各自组内比较MMR-组与MMR+组的辐射剂量、对比剂用量和并发症。
主要发现
- EVAR对比剂用量:MMR+组28.2±10.2 g vs MMR-组32.9±10.6 g(P=.009)。
- TEVAR对比剂用量:MMR+组26.9±7.8 g vs MMR-组31.7±11.5 g(P=.009)。
- TEVAR辐射暴露:MMR+组638±463 mGy vs MMR-组872±623 mGy(P=.033)。
- TEVAR手术时间:MMR+组86.2±23.9分钟 vs MMR-组96.4±27.0分钟(P=.023)。
- EVAR和TEVAR组中入路损伤及其他并发症发生率相似。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Endovascular procedures for aortic aneurysm repair have become widely accepted as safe and effective surgical options. We investigated the efficacy of the multimodality roadmap (MMR) system with biplane fluoroscopy to attempt to reduce the use of contrast medium and exposure to radiation during surgery. METHODS: We retrospectively reviewed 263 consecutive cases with elective endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR). Patients were categorized into two groups, with and without introduction of the MMR system, which was applied in 164 patients (62.4%). The MMR- group included 62 EVAR and 37 TEVAR cases, and the MMR+ group consisted of 81 EVAR and 83 TEVAR cases. Radiation dose, contrast medium use, and complications were compared between the MMR- and MMR+ groups in the respective EVAR and TEVAR groups. RESULTS: There was a significantly lower amount of contrast medium use in the MMR+ group compared with the MMR- group in EVAR (32.9 ± 10.6 g and 28.2 ± 10.2 g; P = .009) and TEVAR (31.7 ± 11.5 g and 26.9 ± 7.8 g; P = .009). In addition, significantly lower radiation exposure was observed in the MMR+ group of TEVAR (872 ± 623 mGy vs 638 ± 463 mGy; P = .033). The operative time of the MMR+ group was significantly shorter for patients with TEVAR compared with the MMR- group (96.4 ± 27.0 minutes vs 86.2 ± 23.9 minutes; P = .023). The incidence of access injury and other complications was similar in both EVAR and TEVAR groups. CONCLUSIONS: The MMR system with three-dimensional fusion imaging can reduce the contrast medium dose in EVAR and the exposure to contrast medium and radiation in TEVAR.
引用
- Hiraoka A, Shiraya S, Chikazawa G, et al. Feasibility of three-dimensional fusion imaging with multimodality roadmap system during endovascular aortic repair. J Vasc Surg. 2018. PMID: 29615355. doi:10.1016/j.jvs.2017.12.065
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。