文献速递主动脉疾病

肾下型、近肾型及肾上型腹主动脉瘤腔内修复术中脑栓塞、高风险操作及相关神经结局

Cerebral embolization during endovascular infrarenal, juxtarenal, and suprarenal aortic aneurysm repair, high-risk maneuvers, and associated neurologic outcomes.
PubMed 文献 · J Vasc Surg · 2018-01-01

本研究对60例接受腹主动脉瘤腔内修复术的患者进行围术期持续左侧经颅多普勒监测,发现胸主动脉腔内修复(TEVAR)和烟囱支架的脑栓塞总数显著高于标准分叉支架,导丝和猪尾导管置入为最高风险操作,较高的围术期栓塞负荷与中期词语表回忆认知下降相关,但与谵妄或卒中发生率无关。

要点

  • TEVAR和烟囱支架的脑栓塞数显著高于标准分叉支架(均值36.2和13.39 vs 5.81,P<.05)。
  • 导丝和猪尾导管置入是所有术式(包括肾下型修复)中最高风险的操作。
  • 较高围术期栓塞负荷与中期词语表回忆认知下降相关,但与谵妄或卒中无关。

核心结论

  • 患者在多种腹主动脉腔内手术中均有脑栓塞风险,TEVAR仍是风险最高的术式。
  • 目前尚无经过验证的保护措施可预防脑栓塞及其相关的临床和亚临床神经损伤风险。

研究设计与样本

  • 前瞻性研究,60例患者接受腹主动脉瘤腔内修复术并连续左侧围术期经颅多普勒监测。
  • 分组:肾下型动脉瘤分叉支架18例,腔内动脉瘤封堵支架16例,腔内动脉瘤封堵加肾动脉烟囱支架17例,胸主动脉瘤3例。
  • 手术对 stiff wire 置入和支架释放等事件进行时间戳标记;术前和术后90天进行认知测试组合。

主要发现

  • TEVAR和烟囱支架的总操作栓塞数显著高于标准分叉支架(均值36.2和13.39 vs 5.81,P<.05)。
  • 导丝和猪尾导管置入是最高风险操作,所有术式包括肾下型动脉瘤修复均如此。
  • 较高的围术期栓塞负荷与中期词语表回忆认知下降相关,但与谵妄或卒中发生率无关。
  • 认知下降风险与手术类型无关。
  • 抗血小板药物使用未显示出保护作用。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Risk factors for postoperative cognitive decline after noncardiac surgery are multifactorial and poorly understood. Evidence suggests that perioperative microembolic damage to the brain on movement of wires and catheters during endovascular aortic procedures may play an important role. Endovascular aortic aneurysm repair requires invasive manipulation of wires and cannulas within the aorta, but research into cerebral emboli during aortic aneurysm repair and cognitive or neurologic injury is scarce and limited to thoracic aneurysms. This study prospectively studied embolic phenomena detected in the middle cerebral artery during infrarenal, juxtarenal, and thoracic endovascular aortic repair (TEVAR) and investigated links to delirium, stroke, and postoperative cognitive decline. METHODS: There were 60 patients who received continuous left-sided perioperative transcranial Doppler monitoring during endovascular aortic aneurysm repair (bifurcated graft for infrarenal aneurysm, n = 18; endovascular aneurysm sealing graft, n = 16; endovascular aneurysm sealing and renal "chimney" stent, n = 17; and thoracic aneurysm, n = 3). The procedure was time stamped for events such as stiff wire insertion and graft deployment. A battery of cognitive tests designed to test several cognitive domains were performed preoperatively and at 90 days postoperatively. RESULTS: TEVAR and chimney grafts demonstrated significantly greater numbers of total procedural emboli compared with standard bifurcated grafts (mean emboli, 36.2 and 13.39, respectively; bifurcated graft, 5.81; P < .05). The highest risk maneuvers were guidewire and pigtail catheter insertion. This was the case for all procedures including infrarenal aneurysm repair. A higher perioperative embolic load was associated with medium-term cognitive decline in list recall but not with incidence of delirium or stroke. Risk of cognitive decline did not relate to procedure type. Antiplatelet use failed to demonstrate a protective effect. CONCLUSIONS: Patients are at risk of cerebral emboli during several types of endovascular aortic surgery, although TEVAR remains the highest risk procedure. As yet, there are no validated protective measures available to prevent cerebral emboli and their associated risks of clinical and subclinical neurologic injury.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Benson RA, Matthews D, Loftus V, et al. Cerebral embolization during endovascular infrarenal, juxtarenal, and suprarenal aortic aneurysm repair, high-risk maneuvers, and associated neurologic outcomes. J Vasc Surg. 2018. PMID: 29685515. doi:10.1016/j.jvs.2018.01.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。