STABILISE技术治疗B型主动脉夹层的满意短期结果
本研究评估了本机构一年内采用STABILISE技术治疗急性复杂性主动脉夹层患者的围手术期和短期结果。2016年6月至2017年6月,10例患者(均为男性,平均年龄62.6±7.4岁)接受治疗。30天技术和临床成功率为100%,胸段假腔完全血栓形成,无I型内漏。结论认为该技术安全可行,但需进一步研究长期效果。
要点
- 30天技术和临床成功率为100%,胸段假腔完全血栓形成。
- 无主动脉破裂,无需开放手术转换。
- 短期随访主动脉直径稳定,无进一步扩张。
核心结论
- STABILISE技术在该队列中安全可行,多数病例实现胸段假腔完全血栓形成和单腔化主动脉。
- 需要进一步研究以确定治疗主动脉的长期行为。
研究设计与样本
- 单中心队列研究,纳入2016年6月至2017年6月本机构收治的10例急性复杂性主动脉夹层患者(均为男性,平均年龄62.6±7.4岁)。
- 采用STABILISE技术治疗,术后第一周出院前、3个月、6个月及每年行计算机断层扫描(CT)随访。
主要发现
- 30天技术和临床成功率均为100%,胸段假腔完全血栓形成,无I型内漏。
- 所有病例灌注不良均得到解决;无主动脉破裂记录,无需开放手术转换。
- 1例延迟性脊髓缺血在出院期内完全缓解。
- 出院前CT显示所有病例胸段假腔完全血栓形成;2例观察到腹段假腔有一定程度通畅。
- 短期随访中,整体主动脉直径保持稳定,无进一步扩张。
临床怎么用
- 作者认为STABILISE技术在该队列中安全可行,可用于急性复杂性主动脉夹层。
- 作者指出需要进一步研究以确定治疗主动脉的长期行为。
局限性
- 需要进一步研究以确定治疗主动脉的长期行为。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to evaluate the perioperative and short-term results in a cohort of patients treated during the last year at our institution with the stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique for acute complicated aortic dissection. METHODS: Between June 2016 and June 2017, 10 patients (all male; mean age, 62.6 ± 7.4 years) received treatment for acute complicated aortic dissection with the STABILISE technique. After a standard provisional extension to induce complete attachment procedure using the commercially available endovascular dissection system (Cook Medical, Bloomington, Ind), the distal stent graft area and the bare stent area were ballooned to completely exclude the thoracic false lumen (FL) and to obtain a single-channeled abdominal aorta. Computed tomography was routinely performed within the first postoperative week before discharge and then at 3 months, at 6 months, and yearly thereafter. The technical and clinical success rates were analyzed. RESULTS: The 30-day technical and clinical success rates were 100%, with complete thrombosis of the thoracic FL and no type I endoleak. Malperfusion was resolved in all cases. No aortic ruptures were recorded, and no open conversion was required. One case of delayed spinal cord ischemia fully resolved within the discharge period. Predischarge computed tomography showed complete thrombosis of the thoracic FL in all cases. In two cases, some degree of patency of the abdominal FL was observed. At short-term follow-up, the overall aortic diameters remained stable with no further dilation. CONCLUSIONS: The STABILISE technique was safe and feasible in this cohort of patients, with complete thrombosis of the thoracic FL and creation of a single-channeled aorta in most cases. Further studies are needed to ascertain the long-term behavior of the treated aorta.
引用
- Melissano G, Bertoglio L, Rinaldi E, et al. Satisfactory short-term outcomes of the STABILISE technique for type B aortic dissection. J Vasc Surg. 2018. PMID: 29606568. doi:10.1016/j.jvs.2018.01.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。