文献速递血液透析通路

动静脉比值指数与自体桡头动静脉瘘主要功能成熟的独立关联

Independent association of arteriovenous ratio index on the primary functional maturation of autologous radiocephalic arteriovenous fistula.
PubMed 文献 · J Vasc Surg · 2018-03-08

该前瞻性单中心队列研究纳入324例接受桡头动静脉瘘(RCAVF)的患者,评估动静脉比值(AVR)指数与主要功能成熟(FM)的关联。多因素分析显示AVR指数是FM的唯一独立相关因素(P=0.001;95%CI 0.08-0.26),AVR为1至1.06时FM达100%。

要点

  • AVR指数是RCAVF主要功能成熟的唯一独立相关因素(P=0.001)。
  • AVR为1至1.06时RCAVF的FM发生率为100%。
  • AVR偏离此范围与FM逐步降低相关(P<.05)。

核心结论

  • 所提出的新型测量技术(AVR指数)是RCAVF主要功能成熟的独立预测因素。
  • 研究提示,无论其他变量如何,最小直径不匹配(AVR 1-1.06)对RCAVF的最佳血流动力学及其主要功能成熟至关重要。

研究设计与样本

  • 前瞻性连续单中心队列研究,意向性治疗分析,纳入324例在4年期间接受RCAVF的患者。
  • 通过单变量和多变量逻辑回归分析评估人口学、解剖因素、侧别、合并症、麻醉类型、术中震颤、吻合角度和AVR指数与FM终点的关系。
  • AVR取三位小数以确保最大准确性,通过受试者工作特征曲线确定最佳敏感性和1-特异性。
  • 采用χ2(亚组)分析研究不同AVR范围内FM发生率的差异。
  • P值<.05视为显著,效应量以比值比及其95%置信区间报告。

主要发现

  • 在所有变量中,AVR指数是RCAVF主要功能成熟的唯一独立相关因素(66%;n=214/324)(P=.001;95%CI 0.08-0.26)。
  • AVR为1至1.06时RCAVF的FM发生率为100%。
  • AVR低于或高于此范围与RCAVF的FM逐步降低相关(P<.05)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: It has been hypothesized that a novel measurement technique of arteriovenous ratio (AVR) index obtained from inflow (radial artery diameter) to that of outflow (cephalic vein diameter) and its application through the Bernoulli effect has no impact on the primary functional maturation (FM) of autogenous radiocephalic arteriovenous fistula (RCAVF). METHODS: A prospective consecutive single-center cohort study with intention to treat of 324 patients undergoing RCAVF during a period of 4 years was conducted. Variables of demographics, anatomic factors, laterality, comorbidities, anesthesia type, presence of intraoperative thrill, angle of anastomosis, and AVR index were assessed through univariate and multivariate logistic regression analysis on the end point of FM. The AVR was subjected to three decimal points to ensure maximal accuracy for best sensitivity and 1 - specificity by receiver operating characteristic curve. The χ2 (subgroup) analyses were undertaken to investigate the differences in FM incidence within different ranges of AVR. Test of probability (P value) was considered to be significant with P < .05. Effect sizes were reported as odds ratio with their measure of uncertainty at 95% confidence intervals. RESULTS: Among all variables, the AVR index remained the only independent factor associated with FM (66%; n = 214/324) of RCAVFs (P = .001; 95% confidence interval, 0.08-0.26). AVR of 1 to 1.06 was associated with 100% FM in RCAVFs. Decrease or increase of this index was associated with stepwise reduction in FM of RCAVFs (P < .05). CONCLUSIONS: The suggested novel measurement technique (AVR index) is an independent predictor of FM in RCAVFs. This study implies that minimal diameter (ie, inflow artery dimeter to outflow cephalic vein diameter) mismatch (AVR, 1-1.06) irrespective of other variables remains crucial for optimal hemodynamics (pressure and velocity) of RACVFs and their primary FM.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Kordzadeh A, Askari A, Panayiotopoulos Y, et al. Independent association of arteriovenous ratio index on the primary functional maturation of autologous radiocephalic arteriovenous fistula. J Vasc Surg. 2018. PMID: 29526374. doi:10.1016/j.jvs.2017.10.082

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。