文献速递颈动脉与弓上血管

基于全国数据库比较颈动脉内膜切除术中分流方式与脑监测技术的疗效

Comparing the efficacy of shunting approaches and cerebral monitoring during carotid endarterectomy using a national database.
PubMed 文献 · J Vasc Surg · 2018-03-20

研究基于血管质量倡议数据库2012年10月至2015年4月的28457例颈动脉内膜切除术,比较常规分流、选择性分流与从不分流及不同脑监测方式的实践模式和结局。未校正分析中唤醒监测组院内死亡低于常规分流组,但多因素校正后各组主要结局无差异。

要点

  • 共纳入28457例颈动脉内膜切除术,常规分流14128例、选择性分流12489例、从不分流1740例。
  • 未校正院内死亡率:唤醒监测组0.05% vs 常规分流组0.30%(P = .037)。
  • 多因素校正后各组主要结局无差异,唤醒监测组术后住院时间更短(1.55天 vs 2.00天,P < .01)。

核心结论

  • 血管质量倡议注册分析显示,不同分流与脑监测方式的未校正院内死亡和卒中率相当,但唤醒监测组未校正死亡率低于常规分流组。
  • 风险校正分析后各组间任何主要结局均无差异,鉴于各方式临床等效,作者认为进一步工作应评估这些技术的相对成本。

研究设计与样本

  • 回顾性分析血管质量倡议数据库2012年10月至2015年4月录入的颈动脉病例,排除合并其他手术及分流信息不完整的病例。
  • 共纳入28457例颈动脉内膜切除术,分为常规分流14128例、从不分流1740例、选择性分流12489例。
  • 选择性分流组再分为唤醒监测2052例、脑电图监测6144例、残端压力监测2310例。
  • 采用多因素logistic回归模型校正危险因素以识别各结局的预测因素。

主要发现

  • 未校正院内死亡率:常规分流0.30%(95%CI 0.21-0.39)vs 选择性分流0.22%(95%CI 0.14-0.31)。
  • 未校正院内卒中率:常规分流0.78%(95%CI 0.64-0.93)vs 选择性分流0.91%(95%CI 0.75-1.08)。
  • 唤醒监测组未校正院内死亡率低于常规分流组(0.05% vs 0.30%;P = .037)。
  • 多因素校正后各组任何主要结局均无差异。
  • 唤醒监测组术后住院时间短于常规分流组(1.55天 vs 2.00天;P < .01)。

关键数值与推荐

  • 未校正院内死亡和卒中率在常规分流与选择性分流间相近,唤醒监测组未校正死亡率低于常规分流组。
  • 风险校正后各组主要结局无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Carotid endarterectomy practice patterns, including the use of shunts and cerebral monitoring techniques, are typically surgeon-dependent and differ greatly on a national level. Prior literature evaluating these techniques is often underpowered for detecting variations in low-frequency outcomes. The purpose of this study was to evaluate current carotid endarterectomy practice patterns and to allow comparison across surgical approaches using a large national database. METHODS: We divided carotid cases entered into the Vascular Quality Initiative database between October 2012 and April 2015 into routine shunting, selective shunting, and never shunting cohorts, excluding endarterectomies performed with concomitant procedures and those with incomplete information on the use of a shunt. The selective group was subdivided into cases with awake, electroencephalography, and stump pressure monitoring. We evaluated differences in practice patterns and compared rates of stroke, death, return to the operating room, reperfusion injury, and re-exploration after closure across these groups. Multivariate logistic regression models adjusting for risk factors were used to identify predictors of each outcome. RESULTS: Between October 2012 and April 2015, there were a total of 28,457 endarterectomies included in our analysis, of which 14,128 involved routine shunting, 1740 involved never shunting, and 12,489 involved selective shunting. Of the selective cases, 6144 involved electroencephalography monitoring, 2310 involved stump pressure monitoring, and 2052 involved awake monitoring. Unadjusted rates of in-hospital death and stroke were 0.30% (95% confidence interval [CI], 0.21-0.39) and 0.78% (95% CI, 0.64-0.93) for routine shunting and 0.22% (95% CI, 0.14-0.31) and 0.91% (95% CI, 0.75-1.08) for selective shunting, respectively. The unadjusted rate of in-hospital death was lower in the awake monitoring group than in the routine shunting group (0.05% vs 0.30%; P = .037). After adjustment for patient risk factors, the multivariate models showed no difference in rates of any primary outcomes among the groups, although there was a shorter postoperative length of stay for the awake monitoring group compared with the routine shunting group (1.55 days vs 2.00 days, respectively; P < .01). CONCLUSIONS: Analysis of the Vascular Quality Initiative registry shows equivalent unadjusted rates of in-hospital death and stroke across different approaches to shunting and cerebral monitoring with the exception of the awake monitoring group, which has lower unadjusted mortality compared with the routine shunting group. In the risk-adjusted analysis, however, there are no differences across any of the groups. Given the clinical equivalence of approaches to shunting and cerebral monitoring, further work should evaluate the relative cost of these techniques.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Wiske C, Arhuidese I, Malas M, et al. Comparing the efficacy of shunting approaches and cerebral monitoring during carotid endarterectomy using a national database. J Vasc Surg. 2018. PMID: 29571621. doi:10.1016/j.jvs.2017.11.077

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。