能否提高脊髓缺血的识别能力?在急性器械固定猪模型中应用运动诱发电位、血清标志物与呼出气体分析
在9头雌性德国长白猪中建立胸腹主动脉修复相关脊髓缺血模型,联合经颅运动诱发电位、血清神经元损伤标志物与呼出气体挥发性有机化合物分析。结果:永久结扎血管较钳夹导致更差神经结局和更多坏死运动神经元;血清标志物变化无特异性;呼出丙酮和异丙醇在剖腹术后浓度最高,戊烷和己烷在缺血再灌注损伤期间升高。呼出挥发性有机化合物或可为常规监测提供补充信息。
要点
- 永久结扎较序贯钳夹导致更差神经结局和更多坏死运动神经元。
- 血清神经元损伤标志物变化无特异性。
- 呼出丙酮和异丙醇在剖腹术后浓度最高,戊烷和己烷在缺血再灌注期间升高。
核心结论
- 呼出挥发性有机化合物可反映手术期间的代谢应激和缺血再灌注所致氧化损伤,或可为常规监测方法提供补充信息。
- 为模拟人类主动脉瘤修复时的脊髓缺血,动物模型须就血管解剖与功能进行细致评估。
研究设计与样本
- 在9头雌性德国长白猪中开展动物实验,行胸-膈-腹切开术后,通过序贯钳夹(n=4)或永久结扎(n=5)腹主动脉和胸主动脉的节段动脉(caudocranial方向)直至tc-MEPs较基线下降至少25%以诱导脊髓缺血。
- 监测包括经颅运动诱发电位(tc-MEPs)、血中神经元损伤标志物,以及呼出气中挥发性有机化合物(VOCs)分析(固相微萃取结合气相色谱-质谱联用)。
- 苏醒后评估临床和神经状态(Tarlov评分),死后取脊髓组织行组织学检查。
主要发现
- 永久血管结扎较钳夹诱导更差的神经结局和更高数量的坏死运动神经元。
- 血清标志物变化无特异性。
- 剖腹术后呼出丙酮和异丙醇浓度最高,戊烷和己烷在缺血再灌注损伤期间升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Paraplegia due to spinal cord ischemia (SCI) is a serious complication after repair of thoracoabdominal aortic aneurysms. For prevention and early treatment of spinal ischemia, intraoperative monitoring of spinal cord integrity is essential. This study was intended to improve recognition of SCI through a combination of transcranial motor-evoked potentials (tc-MEPs), serum markers, and innovative breath analysis. METHODS: In 9 female German Landrace pigs, tc-MEPs were captured, markers of neuronal damage were determined in blood, and volatile organic compounds (VOCs) were analyzed in exhaled air. After thoraco-phrenico-laparotomy, SCI was initiated through sequential clamping (n = 4) or permanently ligating (n = 5) SAs of the abdominal and thoracic aorta in caudocranial orientation until a drop in the tc-MEPs to at least 25% of the baseline was recorded. VOCs in breath were determined by means of solid-phase microextraction coupled with gas chromatography-mass spectrometry. After waking up, clinical and neurological status was evaluated (Tarlov score). Spinal cord histology was obtained in postmortem. RESULTS: Permanent vessel ligature induced a worse neurological outcome and a higher number of necrotic motor neurons compared to clamping. Changes of serum markers remained unspecific. After laparotomy, exhaled acetone and isopropanol showed highest concentrations, and pentane and hexane increased during ischemia-reperfusion injury. CONCLUSIONS: To mimic spinal ischemia occurring in humans during aortic aneurysm repair, animal models have to be meticulously evaluated concerning vascular anatomy and function. Volatiles from breath indicated metabolic stress during surgery and oxidative damage through ischemia reperfusion. Breath VOCs may provide complimentary information to conventional monitoring methods.
引用
- Püschel A, Ebel R, Fuchs P, et al. Can Recognition of Spinal Ischemia Be Improved? Application of Motor-Evoked Potentials, Serum Markers, and Breath Gas Analysis in an Acutely Instrumented Pig Model. Ann Vasc Surg. 2018. PMID: 29518504. doi:10.1016/j.avsg.2018.01.095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。