文献速递主动脉疾病外周动脉疾病

日本腹主动脉瘤患者标准EXCLUDER支架治疗后髂动脉分叉支架的解剖适用性

Anatomical Suitability of the GORE EXCLUDER Iliac Branch Endoprosthesis in Japanese Patients with Common Iliac Aneurysms Treated by Standard EXCLUDER Endografts.
PubMed 文献 · Ann Vasc Surg · 2018-02-28

本研究回顾性分析2007年6月至2017年1月在本中心接受择期EVAR并使用EXCLUDER支架的202例主髂动脉瘤患者,其中髂内动脉因髂外动脉锚定区被栓塞者纳入。通过三维工作站分析术前CT评估EXCLUDER髂动脉分叉支架的适用性。结果显示48个髂段中15个(31.3%)适合单侧植入,双侧髂动脉瘤患者中仅2个(16.7%)髂段适合双侧植入。髂总动脉管径不足和肾动脉至髂内动脉长度不足是主要解剖限制。

要点

  • 31.3%的受累髂内动脉若使用髂动脉分叉支架可得以保留。
  • 双侧植入仅适用于少数病例,肾动脉至髂内动脉长度不足是主要障碍。
  • 髂总动脉管腔直径不足是单侧植入最常见的解剖限制。

核心结论

  • 若使用髂动脉分叉支架,31.3%的受累髂内动脉可得以保留。
  • 双侧植入似乎仅在有限病例中可行。
  • 除髂总动脉管腔小外,肾动脉至髂内动脉长度不足也是主要解剖限制,尤其计划双侧植入时。

研究设计与样本

  • 回顾性分析2007年6月至2017年1月在本中心接受择期EVAR并使用EXCLUDER支架的主髂动脉瘤患者202例。
  • 纳入髂内动脉因髂外动脉锚定区被栓塞的患者,排除直径<25 mm的单侧或小髂总动脉瘤。
  • 使用三维工作站分析术前CT扫描,按照使用说明书评估髂动脉分叉支架的适用性。

主要发现

  • 共纳入12例双侧髂总动脉瘤和24例单侧髂总动脉瘤患者。
  • 48个髂段中15个(31.3%)适合单侧髂动脉分叉支架植入。
  • 40%的髂总动脉瘤管腔直径不足,是单侧植入最常见的障碍。
  • 12例双侧髂总动脉瘤患者的髂段中2个(16.7%)适合双侧植入。
  • 肾动脉至髂内动脉长度不足是双侧植入的主要障碍。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The EXCLUDER iliac branch endoprosthesis (IBE) is designed to exclude a common iliac artery (CIA) aneurysm (CIAA), preserving the internal iliac artery (IIA) during endovascular aneurysm repair (EVAR). We assessed the anatomical suitability of the IBE in patients whose aortoiliac aneurysms (AIAs) had already been treated with a standard EXCLUDER endograft, compromising their IIAs. METHODS: From June 2007 to January 2017, 202 patients underwent elective EVAR for AIAs with the EXCLUDER endograft at our institute. Among them, patients whose IIAs were embolized for the external iliac artery (EIA) landing were included in this study. Patients with solitary or small CIAAs of <25 mm in diameter were excluded. Preoperative computed tomography scans were analyzed using a 3D workstation to evaluate the suitability of the IBE when following its instructions for use. RESULTS: Twelve patients with bilateral CIAAs and 24 patients with unilateral CIAAs were enrolled in this study. Among the 48 iliac segments, 15 (31.3%) were eligible for unilateral IBE implantation. A total of 40% of the CIAAs did not have a large enough luminal diameter, which was the most common barrier to the use of the unilateral IBE in our patients. Among the iliac segments of the 12 patients with bilateral CIAAs, 2 (16.7%) were suitable for bilateral implantation. An insufficient length between the renal artery (RA) and the IIA was the major barrier to the use of bilateral IBE. CONCLUSIONS: A total of 31.3% of the compromised IIAs could have been preserved if the IBE was used. Bilateral implantation seemed possible in a limited number of cases. In addition to a small CIA lumen, an insufficient length between the RA and the IIA was also a predominant anatomical limitation, especially when bilateral implantation was planned.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Sugimoto M, Takahashi N, Niimi K, et al. Anatomical Suitability of the GORE EXCLUDER Iliac Branch Endoprosthesis in Japanese Patients with Common Iliac Aneurysms Treated by Standard EXCLUDER Endografts. Ann Vasc Surg. 2018. PMID: 29499354. doi:10.1016/j.avsg.2017.11.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。