文献速递主动脉疾病内脏/肾动脉与血管畸形

内分支在复杂腹主动脉及胸腹主动脉瘤腔内修复术中应用的早期经验

Early Experience with the Use of Inner Branches in Endovascular Repair of Complex Abdominal and Thoraco-abdominal Aortic Aneurysms.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2018-03-12

本研究前瞻性纳入32例使用内分支支架行开窗/分支腔内修复(F/BEVAR)的复杂腹主动脉瘤或胸腹主动脉瘤患者,技术成功率100%,30天手术死亡率3.1%,1年内分支靶血管支架通畅率91.9%±4.5%。早期数据提示内脏内分支可能成为F/BEVAR处理靶血管的可行第三种选择,内分支联合开窗的配置似乎优于单纯内分支。

要点

  • 32例复杂腹主动脉瘤或胸腹主动脉瘤患者使用内分支支架行F/BEVAR,技术成功率100%。
  • 30天手术死亡率3.1%(1/32),1年估计生存率80.0%±8.3%。
  • 1年内分支靶血管支架通畅率91.9%±4.5%,1年免于再干预率78.4%±8.9%。

核心结论

  • 早期数据提示内脏内分支可能成为F/BEVAR处理选定靶血管的可行第三种选择。
  • 内分支联合开窗的支架配置似乎优于单纯内分支支架。
  • 内分支设计的耐久性需进一步研究。

研究设计与样本

  • 前瞻性收集所有连续接受F/BEVAR并使用内分支支架治疗复杂腹主动脉瘤或胸腹主动脉瘤的患者资料。
  • 共纳入32例患者(28例男性,平均年龄71.6±8.3岁)。
  • 7例(21.9%)为复杂腹主动脉瘤,25例(78.1%)为胸腹主动脉瘤。

主要发现

  • 4例(12.5%)患者使用仅含内分支的支架,其余28例(87.5%)使用含开窗和内分支的支架。
  • 共52根血管以内分支为目标;所有32例(100%)患者技术成功。
  • 含开窗和内分支的支架中全部38根内分支靶血管均即时置管(<1分钟);单纯内分支支架中靶血管置管较困难(<1分钟n=3,1-3分钟n=4,>3分钟n=7)。
  • 30天手术死亡率为3.1%(1/32),1年估计生存率为80.0%±8.3%。
  • 随访期间3例患者共4根肾内分支闭塞;1年内分支靶血管支架通畅率为91.9%±4.5%,1年免于再干预率为78.4%±8.9%。

临床怎么用

  • 早期数据提示内脏内分支可能作为F/BEVAR处理选定靶血管的可行第三种选择(作者认为)。
  • 内分支联合开窗的支架配置似乎优于单纯内分支支架(作者认为)。
  • 内分支设计的耐久性需进一步研究(作者认为)。

局限性

  • 内分支设计的耐久性需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Visceral arteries in fenestrated and branched endovascular repair (F/BEVAR) have been addressed by fenestrations or directional side branches. Inner branches, as used in the arch branched device, could provide an extra option for visceral arteries "unsuitable" for fenestrations or directional side branches. Early experience with the use of inner branches for visceral arteries in F/BEVAR is described. METHODS: All consecutive patients treated by F/BEVAR for complex abdominal aortic aneurysm (AAA) or thoraco-abdominal aneurysm (TAAA) using stent grafts with inner branches were included. Data were collected prospectively. RESULTS: Thirty-two patients (28 male, mean age 71.6 ± 8.3 years) were included. Seven (21.9%) patients had a complex AAA and 25 (78.1%) had a TAAA. A stent graft with inner branches only was used in four (12.5%) patients. The remaining 28 (87.5%) patients received a stent graft with fenestrations and inner branches. In total 52 vessels were targeted with inner branches. Technical success was achieved in all 32 (100%) patients. All 38 inner branch target vessels in grafts including fenestrations and inner branches were instantly catheterised (<1 minute), whereas catheterisation of target vessels in "inner branch only" grafts proved more difficult (<1 minute, n = 3; 1-3 min, n = 4; and >3 min, n = 7). The 30 day operative mortality was 3.1% (1/32). Estimated survival at 1 year was 80.0% ± 8.3%. During follow-up, four renal inner branches occluded in three patients. The estimated inner branch target vessel stent patency at 1 year was 91.9 ± 4.5%. The estimated freedom from re-intervention at 1 year was 78.4% ± 8.9%. CONCLUSIONS: Early data suggest that visceral inner branches might represent a feasible third option to address selected target vessels in F/BEVAR. Stent grafts with inner branch(es) in combination with fenestrations seem to be a better configuration than stent grafts with inner branches alone. Durability of the inner branch design needs further investigation.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Katsargyris A, Marques de Marino P, Mufty H, et al. Early Experience with the Use of Inner Branches in Endovascular Repair of Complex Abdominal and Thoraco-abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg. 2018. PMID: 29545020. doi:10.1016/j.ejvs.2018.01.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。