常规内镜诊断腹主动脉瘤修复术后结肠缺血的准确性:一项Meta分析
该Meta分析纳入12项前瞻性研究共718例腹主动脉瘤修复术后患者,评估常规内镜诊断结肠缺血的准确性。内镜对所有级别结肠缺血的汇总诊断比值比为26.60(95%CI 8.86-79.88),对3级结肠缺血的敏感度为0.52(95%CI 0.31-0.73)、特异度为0.97(95%CI 0.95-0.99)。作者认为常规内镜在排除结肠缺血方面高度准确,但诊断临床相关的透壁性结肠缺血准确性较低,且为安全的常规诊断方法。
要点
- 常规内镜对所有级别结肠缺血的汇总诊断比值比为26.60(95%CI 8.86-79.88)。
- 内镜诊断3级结肠缺血的敏感度为0.52(95%CI 0.31-0.73),特异度为0.97(95%CI 0.95-0.99)。
- 所有类型腹主动脉瘤患者阳性验后概率高达60%,破裂腹主动脉瘤患者为68%。
核心结论
- 常规内镜在排除腹主动脉瘤修复术后结肠缺血方面高度准确。
- 临床医生应知悉内镜在诊断临床相关的透壁性结肠缺血方面准确性较低。
- 内镜是安全的常规诊断方法,因所有研究均未报告不良事件。
研究设计与样本
- 通过Pubmed和Embase数据库检索获得1188篇文章,纳入描述择期或急诊腹主动脉瘤修复术后常规结肠镜或乙状结肠镜检查的前瞻性研究。
- 共纳入12篇文章,包括718例腹主动脉瘤患者,其中44%接受择期手术,56%为破裂腹主动脉瘤,6%接受血管腔内修复。
- 研究质量采用QUADAS-2工具评估,绘制敏感度和特异度森林图,采用随机效应模型计算诊断比值比。
主要发现
- 全部患者中20.8%被识别为结肠缺血(所有级别),6.5%的患者为3级结肠缺血。
- 内镜对所有级别结肠缺血的汇总诊断比值比为26.60(95%CI 8.86-79.88)。
- 内镜检测腹主动脉瘤修复术后3级结肠缺血的敏感度为0.52(95%CI 0.31-0.73),特异度为0.97(95%CI 0.95-0.99)。
- 所有类型腹主动脉瘤患者的阳性验后概率高达60%,破裂腹主动脉瘤患者为68%。
关键数值与推荐
- 内镜诊断所有级别结肠缺血的汇总诊断比值比为26.60(95%CI 8.86-79.88)。
- 内镜诊断3级结肠缺血的敏感度为0.52(95%CI 0.31-0.73),特异度为0.97(95%CI 0.95-0.99)。
- 所有类型腹主动脉瘤患者阳性验后概率高达60%,破裂腹主动脉瘤患者为68%。
临床怎么用
- 原文结论指出常规内镜在排除腹主动脉瘤修复术后结肠缺血方面高度准确。
- 原文结论指出临床医生应知悉内镜在诊断临床相关的透壁性结肠缺血方面准确性较低。
- 原文结论指出内镜是安全的常规诊断方法,因所有研究均未报告不良事件。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Colonic ischaemia (CI) is a devastating complication after abdominal aortic aneurysm (AAA) surgery. The aim of this review was to evaluate the diagnostic test accuracy of routine endoscopy in diagnosing CI after treatment for elective and acute AAA. PATIENTS AND METHODS: The Pubmed and Embase database searches resulted in 1188 articles. Prospective studies describing routine post-operative colonoscopy or sigmoidoscopy after elective or emergency AAA repair were included. The study quality was assessed with the QUADAS-2 tool. Sensitivity and specificity forest plots were drawn. Diagnostic odds ratios were calculated by a random effect model. RESULTS: Twelve articles were included consisting of 718 AAA patients of whom 44% were treated electively, 56% ruptured and, 6% by endovascular repair. Of all patients, 20.8% were identified with CI (all grades), and 6.5% of patients had Grade 3 CI. The pooled diagnostic odds ratio for all grades of CI on endoscopy was 26.60 (95% CI 8.86-79.88). The sensitivity and specificity of endoscopy for detection of Grade 3 CI after AAA repair was 0.52 (95% CI, 0.31-0.73) and 0.97 (95% CI 0.95-0.99) respectively. The positive post-test probability is up to 60% in all kinds of AAA patients and 68% in ruptured AAA patients. CONCLUSION: Routine endoscopy is highly accurate for ruling out CI after AAA repair. Clinicians should be aware that endoscopy is less accurate in diagnosing the presence of the clinically relevant transmural CI. Endoscopy is a safe diagnostic test to use routinely as none of the studies reported adverse events.
引用
- von Meijenfeldt GCI, Vainas T, Mistriotis GA, et al. Accuracy of Routine Endoscopy Diagnosing Colonic Ischaemia After Abdominal Aortic Aneurysm Repair: A Meta-analysis. Eur J Vasc Endovasc Surg. 2018. PMID: 29555253. doi:10.1016/j.ejvs.2018.02.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。