桡动脉-头静脉动静脉内瘘构建后三十天流量预测血液透析功能
这项前瞻性研究在41例建立桡动脉-头静脉动静脉内瘘的终末期肾病患者中,用彩色多普勒超声测量术后1个月和3个月头静脉流出量。结果显示,术后1个月流量≥400 mL/min者1年通畅率为81%,低于低流量组的62%,作者推荐术后30天常规影像检查以发现并纠正低流量患者的狭窄。
要点
- 术后1个月桡动脉-头静脉动静脉内瘘流量≥400 mL/min与更高的血液透析成功率和1年通畅率相关。
- 低流量(<400 mL/min)内瘘未经干预时流量不会显著改善,成熟可能性低。
- 作者建议术后30天对所有患者进行影像检查,以及时发现并纠正低流量患者的狭窄。
核心结论
- 术后第一个月桡动脉-头静脉动静脉内瘘流量≥400 mL/min预测血液透析成功率高于低流量(<400 mL/min),分别为81%和62%。
- 未经干预的低流量不会显著改善,内瘘成熟可能性低。
- 作者建议术后30天对所有患者进行影像检查,以发现并及时纠正低流量患者的狭窄。
研究设计与样本
- 前瞻性研究,纳入45例连续筛查的患者,其中41例被认为适合构建桡动脉-头静脉动静脉内瘘。
- 采用彩色多普勒超声在术后1个月和3个月测量前臂3个头静脉流出部位的血流量。
- 平均年龄70(60-78)岁。
主要发现
- 41例前臂桡动脉-头静脉动静脉内瘘患者中,25例(61%)成功进行动静脉内瘘透析,4例(10%)通过中心静脉导管透析,12例(29%)在术后30天内功能丧失。
- 通畅内瘘30天平均流量为629 ± 305 mL/min,至第3个月增至663 ± 367 mL/min。
- 术后1个月,8/29例(27.6%)流量<400 mL/min;其中2例(25%)血栓形成,3例接受闭合修复者中2例继续血液透析,1例死亡。
- 流量≥400 mL/min的21例中,19例(90%)用于血液透析,2例(10%)内瘘在1年内闭塞,1年时17例功能良好(1年通畅率81%)。
- 低流量内瘘中62%在1年内保持通畅。
临床怎么用
- 作者建议术后30天对所有患者进行影像检查,以识别低流量患者并及时纠正狭窄。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Construction of radiocephalic arteriovenous fistula (RC-AVF) results in successful hemodialysis (HD) in approximately 40% of end-stage renal disease patients. We investigated whether RC-AVF flow measured by ultrasound 30 days postoperative predicted successful HD. METHODS: In this prospective study, color Doppler ultrasound was used to measure cephalic vein outflow volume at 3 forearm sites at 1 and 3 months postoperatively. RESULTS: Of 45 consecutive patients screened for feasibility of RC-AVF by physical examination and US arterial and vein mapping, 41 were considered suitable for construction of RC-AVF. Mean age was 70 (60-78) years. Of the 41 patients who had a forearm RC-AVF, 25 (61%) proceeded to successful AVF dialysis, 4 (10%) had HD via central venous catheter, and 12 (29%) ceased function within the first 30 days postoperatively. The mean flow at 30 days for patent fistulas was 629 ± 305 ml/min and by the third month had increased to 663 ± 367 mL/min. At 1 month, 8/29 (27.6%) patients had a flow rate <400 mL/min. Two (25%) of these clotted, 2 of 3 with closed revisions went on to HD, and 1 died. Of the 21 patients with a flow rate ≥400 mL/min, 19 (90%) functioned for HD, and 2 (10%) AVF occluded before 1 year, resulting in 17 functioning at 1 year (81% 1-year patency). Sixty-two percent of the low-flow fistulas had successful patency within 1 year. CONCLUSIONS: An RC-AVF flow rate of ≥400 mL/min in the first month predicted more successful HD than low flow (<400 mL/min) (81% vs. 62%). Without intervention, low flow rates do not improve significantly and maturation is unlikely. We recommend imaging for all patients at 30 days to identify and promptly correct stenosis in those with low flow rates.
引用
- Pillado E, Behdad M, Williams R, et al. Flow Rates at Thirty Days after Construction of Radiocephalic Arteriovenous Fistula Predict Hemodialysis Function. Ann Vasc Surg. 2018. PMID: 29477679. doi:10.1016/j.avsg.2018.01.068
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。