动静脉瘘成熟的预后因素
本回顾性研究分析了2012年1月至2013年12月期间在单中心创建的146例上肢动静脉瘘,总体成熟率为72%。BMI大于29.5(P=0.026)是瘘管成熟不良的唯一显著负性预测因素,而年龄、瘘管位置和静脉直径均无显著影响。
要点
- 146例上肢动静脉瘘总体成熟率为72%。
- BMI大于29.5(P=0.026)与瘘管成熟不良显著相关。
- 年龄、瘘管位置和静脉直径对成熟无显著影响。
核心结论
- 在本机构使用直径至少2.5 mm的静脉时,总体瘘管成熟成功率为72%。
- BMI大于29.5是瘘管成熟唯一的负性显著预测因素。
- 作者认为,年龄、性别和瘘管位置不应作为静脉直径至少2.5 mm患者考虑动静脉瘘创建的限制因素。
研究设计与样本
- 回顾性病历审查,纳入2012年1月至2013年12月期间在单中心接受上肢动静脉瘘创建的患者。
- 共创建146例瘘管,涉及136例患者;中位年龄68岁,中位BMI为27.8。
- 术前超声评估静脉直径,小于2.5 mm的静脉未用于瘘管创建。
- 瘘管成熟成功定义为瘘管作为血液透析主要通路使用3个月或以上。
主要发现
- 105例瘘管被使用3个月或以上,总体成熟率为72%。
- BMI大于29.5(P=0.026)对瘘管成熟成功有负性影响。
- 年龄、瘘管位置和静脉大小对瘘管成熟无显著影响。
- 男性创建91例瘘管,女性55例;92%患者有高血压,57%有糖尿病,33%有冠状动脉病。
- 60%瘘管为头臂型,24%为贵要静脉转位,16%为桡头型;中位静脉直径为3.7(范围2.5-8.8)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Recent studies have reported successful arteriovenous (AV) fistula maturation rates between 40% and 80%, with older age, distal fistula location, and small vein diameter associated with greater failure rates. Our objective is to determine if these findings are consistent with the outcomes at our institution. METHODS: A retrospective chart review was performed on patients who underwent upper extremity AV fistula creation at a single institution. Patient demographics and risk factors were analyzed, as well as fistula location and vein diameter based on preoperative ultrasound. Veins less than 2.5 mm were not used for fistula creation. Successful fistula maturation was defined as the fistula serving as the primary access for hemodialysis for 3 months or greater. Pearson Chi-Square, Fisher's Exact Test, and Mann-Whitney U-tests were used to determine significant associations. RESULTS: Between January 2012 and December 2013, 146 fistulas were created in 136 patients. The median age was 68. Median body mass index (BMI) was 27.8. Ninety-one fistulas were created in men and 55 in women. Ninety-two percent of patients had hypertension, 57% had diabetes, and 33% had coronary artery disease. Sixty percent of fistulas created were brachiocephalic, 24% were basilic vein transpositions, and 16% were radiocephalic. Median vein diameter was 3.7 (range 2.5-8.8). Eighty-four percent of patients were on hemodialysis at the time of fistula creation, and 21% had a prior fistula. One hundred five fistulas were accessed for 3 months or more, resulting in a successful overall maturation rate of 72%. BMI greater than 29.5 (P = 0.026) negatively impacted successful fistula maturation, whereas age, fistula location, and vein size did not. CONCLUSIONS: We noted a successful overall maturation rate of 72% at our institution when veins at least 2.5 mm in diameter were used. Our sole negative significant predictor for fistula maturation was BMI greater than 29.5. Therefore, in our experience, age, sex, and fistula location should not be used to preclude patients with a vein diameter of at least 2.5 mm from consideration for AV fistula creation.
引用
- Chan C, Ochoa CJ, Katz SG, et al. Prognostic Factors for Arteriovenous Fistula Maturation. Ann Vasc Surg. 2018. PMID: 29477678. doi:10.1016/j.avsg.2018.01.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。