文献速递主动脉疾病

定制Treovance®腹主动脉瘤腔内移植物矫正管状移植物套叠技术晚期失败

A Custom-Made Treovance® Abdominal Aortic Aneurysm Endograft to Correct Late Failure of Trombone Technique with a Tube Endograft.
PubMed 文献 · Ann Vasc Surg · 2018-02-05

本文报告一例56岁马凡综合征患者,既往用两枚Endofit管状移植物以套叠技术行EVAR后出现Ib型内漏致腹主动脉瘤增大,因不适合开放手术且开窗EVAR和烟囱技术被排除,改用定制近端直径44 mm的分叉型Bolton Medical Treovance装置治疗,获得技术和临床成功,6个月随访移植物通畅且无任何类型内漏。作者认为该替代技术有前景,需长期随访。

要点

  • 定制近端直径44 mm分叉型Treovance装置用于套叠技术后Ib型内漏。
  • 术后无即刻或围手术期并发症,6个月随访移植物通畅且无内漏。
  • 作者认为该技术有前景,需长期随访。

核心结论

  • 作者认为这种处理不良近端瘤颈的替代技术有前景,需长期随访,并在定制器械监管的更广泛背景下讨论了该问题。

研究设计与样本

  • 病例报告:一例56岁马凡综合征男性,既往用两枚Endofit管状移植物以套叠技术行EVAR后出现Ib型内漏致腹主动脉瘤增大。

主要发现

  • 患者接受定制近端直径44 mm的分叉型Bolton Medical Treovance装置治疗,获得技术和临床成功。
  • 未观察到即刻或围手术期并发症。
  • 6个月随访显示移植物通畅,无任何类型内漏。

临床怎么用

  • 患者被认为不适合开放手术,且开窗EVAR和烟囱技术等可能替代方案被排除,作者采用定制分叉型Treovance装置治疗。

局限性

  • 作者指出该技术需长期随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Unfavorable anatomy is one of the major limitations of endovascular aortic aneurysm repair (EVAR) with specifically adverse proximal neck morphology excluding many patients from receiving the standard endograft devices. Thoracic tube endografts have been used to overcome the issue of wide infrarenal necks, either as a sole device (single tubes or double tubes using the trombone technique) or as the proximal part of a bifurcated device fixed to the aortic bifurcation or infrarenally oriented. However, custom-made large proximal diameter bifurcated endograft designs have never been used. METHODS: We present the case of a 56-year-old man with Marfan syndrome, suffering abdominal aortic aneurysm (AAA) enlargement from a type Ib endoleak after previous EVAR with 2 Endofit tube endografts (trombone technique). He was considered unfit for open surgery while possible alternatives such as fenestrated endovascular AAA repair and chimney technique were excluded. RESULTS: The patient was treated with a custom-made 44-mm proximal diameter, bifurcated Bolton Medical Treovance device with technical and clinical success. No immediate or perioperative complications were noted. Follow-up after 6 months showed graft patency and no endoleak of any type. CONCLUSIONS: This alternative technique for hostile proximal neck management is promising and needs long-term follow-up; an issue which is discussed within the broader context of custom-made device regulations.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Georgiadis GS, Argyriou C, Valsamidou CD, et al. A Custom-Made Treovance® Abdominal Aortic Aneurysm Endograft to Correct Late Failure of Trombone Technique with a Tube Endograft. Ann Vasc Surg. 2018. PMID: 29421425. doi:10.1016/j.avsg.2017.10.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。