文献速递主动脉疾病

肾下腹主动脉修复联合或不联合假腔内置支架(FLIP)用于复杂主动脉夹层的杂交管理

Infrarenal aortic repair with or without false lumen intentional placement of endografts for hybrid management of complex aortic dissection.
PubMed 文献 · J Vasc Surg · 2018-02-03

该研究回顾了16例复杂主动脉夹层患者接受肾下腹主动脉开放修复联合血管内修复的杂交治疗经验,其中4例采用假腔内置支架(FLIP)技术。结果显示围手术期死亡率为6%,中期随访结果良好,FLIP技术可提供远端锚定区并稳定近端夹层。

要点

  • 复杂主动脉夹层杂交治疗中,肾下腹主动脉修复可作为远端锚定区。
  • FLIP技术适用于部分患者,可完全展开支架并保留腰动脉和肋间动脉血流。
  • 围手术期死亡率为6%,中期随访结果良好。

核心结论

  • 肾下腹主动脉杂交修复治疗复杂主动脉夹层具有低并发症率和死亡率,中期结果良好。
  • FLIP技术可为支架提供锚定区,完全展开支架,并可能稳定近端夹层。

研究设计与样本

  • 回顾性分析前瞻性维护的数据库,纳入2006至2017年16例主动脉夹层患者。
  • 患者接受肾下腹主动脉开放修复或置换联合血管内修复,单期或多期进行。

主要发现

  • 干预最常见指征为腹主动脉、胸主动脉或胸腹主动脉瘤的绝对尺寸或快速增长(65%)。
  • 4例采用FLIP技术,以肾下人工血管作为共同远端锚定区。
  • 1例(6%)在等待二期手术时死于动脉瘤破裂(围手术期死亡率6%)。
  • 随访1个月至7年,1例稳定II型内漏,1例后续因动脉瘤疾病行升主动脉弓置换。

临床怎么用

  • 对于复杂主动脉夹层合并胸腹主动脉瘤或灌注不良者,可考虑肾下腹主动脉杂交修复。
  • 在选定患者中,可利用假腔作为支架通道(FLIP)来创造锚定区并稳定近端夹层。

局限性

  • 样本量小(16例),为单中心回顾性研究。
  • FLIP技术仅应用于4例患者,经验有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Aortic dissection (AD) often involves the infrarenal aorta. We review our experience with open infrarenal aortic repair with or without false lumen intentional placement (FLIP) of endografts in the proximal dissected aorta as part of a hybrid strategy to treat complex AD. METHODS: A prospectively maintained database of patients undergoing intervention for AD was reviewed. Data regarding diagnosis, imaging features, nature of the infrarenal repair (one- vs two-stage procedure), endoleaks, need for additional interventions, morbidity, and mortality were collected. RESULTS: Between 2006 and 2017, there were 16 patients with AD with thoracoabdominal aortic aneurysm (TAAA), malperfusion, or both who underwent open infrarenal aortic repair or replacement combined with endovascular repair in a single- or multiple-stage procedure. Fifteen patients had a chronic AD and one patient had an acute AD. The most common indication for intervention was absolute size or rapid growth of the abdominal, thoracic, or thoracoabdominal aortic aneurysm (65%). In four patients with AD, the infrarenal replacement surgical graft was used as a common distal seal zone, allowing FLIP of an endograft to treat the proximal AD. Ten (62%) cases were done in two or more stages. Three patients had infrarenal aortic replacement with debranching only. In two of these patients, the proximal dissected aorta has remained stable without aneurysmal degeneration. One patient died as a result of rupture of his aneurysm while awaiting the second stage (perioperative mortality, 6%). Patients were observed from 1 month to 7 years. One patient had a stable type II endoleak, and one patient required subsequent replacement of ascending aortic arch for aneurysmal disease. One patient died of unrelated causes on follow-up. CONCLUSIONS: Hybrid infrarenal aortic repair for treatment of complex AD can be performed with low morbidity and mortality and excellent medium-term results. This strategy can resolve malperfusion while simultaneously creating a landing zone using the false lumen as the conduit for the stent graft (FLIP) in selected patients. The FLIP technique allows full expansion of the endograft, potential preservation of lumbar and intercostal artery flow, and exclusion of the weaker false lumen while, in some cases, decompressing and thus stabilizing the proximal dissected aorta.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Quinones-Baldrich WJ, Saleem T, Oskowitz A, et al. Infrarenal aortic repair with or without false lumen intentional placement of endografts for hybrid management of complex aortic dissection. J Vasc Surg. 2018. PMID: 29398314. doi:10.1016/j.jvs.2017.10.078

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。