文献速递主动脉疾病外周动脉疾病

晚期血管内支架移植旋转的预测及其相关发病率与死亡率

Prediction of advanced endovascular stent graft rotation and its associated morbidity and mortality.
PubMed 文献 · J Vasc Surg · 2018-02-01

旋转与髂动脉扭转、钙化体积及支架长度相关,且旋转组终末器官缺血或死亡复合结局(36% vs 0%)及Ib/III型内漏(43% vs 8%)显著更高。术前定量分析髂动脉扭转和钙化有助于风险分层。

要点

  • 晚期EVAR术中支架旋转发生率达37%,平均旋转25°。
  • 髂动脉扭转、钙化体积和支架长度是旋转的预测因素。
  • 旋转组终末器官缺血或死亡及Ib/III型内漏风险显著增加。

核心结论

  • 术中支架旋转患者术后严重并发症发生率显著更高,且与髂动脉扭转、钙化及支架长度强烈相关。

主要发现

  • 支架旋转(≥10°)发生率为37%(n=14),平均旋转25°(IQR 21-28°)。
  • 旋转组总净扭转8.9 ± 0.8 mm-1 vs 4.1 ± 0.5 mm-1(P < .0001),钙化斑块总体积1054 ± 144 mm3 vs 525 ± 83 mm3(P < .01)。
  • 旋转组支架长度172 ± 9 mm vs 156 ± 8 mm(P < .01)。
  • 旋转组终末器官缺血或死亡复合结局36% vs 0%(P = .004)。
  • 旋转组Ib/III型内漏合并率43% vs 8%(P = .03)。

临床怎么用

  • 术前可定量分析髂动脉扭转和钙化,以改善晚期EVAR的风险分层。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Advanced endovascular aneurysm repair (EVAR) with fenestrated and branched stent grafts is increasingly being used to repair complex aortic aneurysms; however, these devices can rotate unpredictably during deployment, leading to device misalignment. The objectives of this study were to quantify the short-term clinical outcomes in patients with intraoperative stent graft rotation and to identify quantitative anatomic markers of the arterial geometry that can predict stent graft rotation preoperatively. METHODS: A prospective study evaluating all patients undergoing advanced EVAR was conducted at two university-affiliated hospitals between November 2015 and December 2016. Stent graft rotation (defined as ≥10 degrees) was measured on intraoperative fluoroscopic video of the deployment sequence. Standard preoperative computed tomography angiography imaging was used to calculate the geometric properties of the arterial anatomy. Any in-hospital and 30-day complications were prospectively documented, and a composite outcome of any end-organ ischemia or death was used as the primary end point. RESULTS: Thirty-nine patients undergoing advanced EVAR were enrolled in the study with a mean age of 75 years (interquartile range [IQR], 71-80 years) and a mean aneurysm diameter of 64 mm (IQR, 59-65 mm). The incidence of stent graft rotation was 37% (n = 14), with a mean rotation of 25 degrees (IQR, 21-28 degrees). A nominal logistic regression model identified iliac artery torsion, volume of iliac artery calcification, and stent graft length as the primary predictive factors. The total net torsion and the total volume of calcific plaque were higher in patients with stent graft rotation, 8.9 ± 0.8 mm-1 vs 4.1 ± 0.5 mm-1 (P < .0001) and 1054 ± 144 mm3 vs 525 ± 83 mm3 (P < .01), respectively. The length of the implanted stent grafts was also higher in patients with intraoperative rotation, 172 ± 9 mm vs 156 ± 8 mm (P < .01). The composite outcome of any end-organ ischemia or death was also substantially higher in patients with stent graft rotation (36% vs 0%; P = .004). In addition, patients with stent graft rotation had significantly higher combined rates of type Ib and type III endoleaks (43% vs 8%; P = .03). CONCLUSIONS: Patients with intraoperative stent graft rotation have a significantly higher rate of severe postoperative complications, and this is strongly associated with higher levels of iliac artery torsion, calcification, and stent graft length. These findings suggest that preoperative quantitative analysis of iliac artery torsion and calcification may improve risk stratification of patients before advanced EVAR.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Crawford SA, Sanford RM, Doyle MG, et al. Prediction of advanced endovascular stent graft rotation and its associated morbidity and mortality. J Vasc Surg. 2018. PMID: 29395426. doi:10.1016/j.jvs.2017.11.061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。