经胸超声评估主动脉弓及降主动脉病变的可行性研究
这项前瞻性病例对照研究纳入40例患者(20例CT确诊胸主动脉病变,20例无病变对照),由对CT结果设盲的超声医师采用优化方案行经胸超声检查。以40 mm为阈值推荐进一步影像检查时,敏感度84%、特异度90%;以35 mm为阈值时,敏感度100%、特异度70%。结论认为经胸超声有望用于胸主动脉病变诊断及CT禁忌患者的随访,但需进一步验证。
要点
- 40 mm阈值下敏感度84%、特异度90%;35 mm阈值下敏感度100%、特异度70%。
- 经胸超声可能作为CT禁忌患者胸主动脉病变随访的替代手段。
核心结论
- 经胸超声有潜力作为胸主动脉病变的诊断手段,并可能用于CT扫描禁忌患者的随访。
- 研究提供概念验证,但需进一步验证和优化技术。
研究设计与样本
- 前瞻性病例对照队列研究,共扫描40例患者(20例CT确诊胸主动脉病变,20例无胸主动脉病变对照)。
- 超声医师对CT结果设盲,记录可视化的病变或扩张主动脉段,比较35 mm与40 mm直径阈值。
主要发现
- 40 mm阈值下,19例病例中16例、20例对照中2例被推荐进一步明确影像检查。
- 35 mm阈值下,19例病例中18例、20例对照中6例被推荐进一步明确影像检查。
- 35 mm阈值敏感度100%、特异度70%;40 mm阈值敏感度84%、特异度90%。
关键数值与推荐
- 直径阈值35 mm时敏感度100%、特异度70%。
- 直径阈值40 mm时敏感度84%、特异度90%。
临床怎么用
- 对CT扫描禁忌的胸主动脉病变患者,可考虑经胸超声作为诊断或随访的替代方式。
- 采用40 mm阈值时特异度较高,采用35 mm阈值时敏感度较高,临床选择阈值需权衡漏诊与过度转诊。
局限性
- 样本量小(共40例),需进一步验证和优化技术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Duplex ultrasonography (DUS) currently has limited applicability in the diagnosis and surveillance of thoracic aortic pathologies because of associated limitations. This study investigates the feasibility of using an optimised DUS protocol to detect descending thoracic aortic pathology. METHODS: This was a prospective, case control cohort study. Patients with computed tomography (CT) confirmed thoracic aortic pathology underwent DUS of the thoracic aorta. A control group known to have no thoracic pathology also underwent DUS. The sonographer performing DUS was blinded to the CT findings, and recorded the presence of pathology or any dilated aortic segment where visualised. Diameter cutoff points of 35 mm and 40 mm were compared. RESULTS: Forty patients were scanned (20 cases and 20 controls). All patients but one had a technically adequate assessment of the thoracic aorta (at least one view of the descending thoracic aorta). Using a size threshold of 40 mm, 16 out of 19 cases and two out of 20 control patients would have been recommended for definitive imaging. Using a cutoff of 35 mm, this became 18 out of 19 cases and six of 20 controls. Sensitivity and specificity were 100% and 70% for a threshold of 35 mm, and 84% and 90% for a threshold of 40 mm. CONCLUSIONS: DUS has the potential to be used as a diagnostic modality for thoracic aortic pathology, and may have a role in surveillance for some patients for whom CT scanning is contraindicated. Further validation and refinements to this technique are required. However, this study provides proof of concept.
引用
- D'Abate F, Oladokun D, La Leggia A, et al. Transthoracic Ultrasound Evaluation of Arch and Descending Thoracic Aortic Pathology. Eur J Vasc Endovasc Surg. 2018. PMID: 29398308. doi:10.1016/j.ejvs.2017.12.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。