新型胸腹主动脉杂交装置SPIDER-graft在猪模型中的可行性研究
本研究在6只家猪中评估新型SPIDER-graft(近端胸降主动脉支架+远端六分支Dacron人工血管)行胸腹主动脉杂交修复的可行性与安全性。结果显示可避免开胸和体外循环,技术成功且无围术期死亡,但需在人体中重新评估。
要点
- SPIDER-graft杂交修复在猪模型中技术可行,避免开胸和体外循环。
- 6只动物均成功植入胸段支架并完成远端开放重建,无围术期死亡。
- 中位胸段支架植入时间4.5分钟,各内脏动脉缺血时间在8-22分钟之间。
核心结论
- 在猪模型中,使用SPIDER-graft行胸腹主动脉杂交修复成功避免了开胸和体外循环,技术可行且安全性初步良好,但需在人体中重新评估。
研究设计与样本
- 可行性及安全性研究,使用6只家猪(75-85 kg),经腹膜后入路暴露腹主动脉及分支,行胸腹主动脉杂交修复术。
主要发现
- 6只动物均成功完成胸段支架植入和远端开放重建,无围术期死亡。
- 中位胸段支架植入时间为4.5分钟。
- 再灌注前中位缺血时间:腹腔干10分钟,肠系膜上动脉8分钟,右肾动脉13分钟,左肾动脉22分钟。
- 血管造影显示支架植入位置合适,血流测量证实所有侧支血流通畅。
临床怎么用
- 该装置可能为胸腹主动脉修复提供一种避免开胸和体外循环的杂交方案,但当前仅限动物实验,临床决策需谨慎。
局限性
- 研究仅纳入6只猪,样本量小,且为动物模型,结果不能直接外推至人体。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The hybrid SPIDER-graft consists of a proximal descending aortic stent graft and a conventional six branched Dacron graft for open abdominal aortic repair. Technical feasibility with regard to avoiding thoracotomy and extracorporeal circulation (ECC) during thoraco-abdominal aortic hybrid repair and peri-procedural safety of this novel device are unknown. MATERIAL AND METHODS: This was a feasibility and safety study in domestic pigs (75-85 kg). The abdominal aorta including iliac bifurcation, left renal artery, and visceral arteries were exposed via retroperitoneal access. The right iliac branch was first temporarily anastomosed end to side to the distal aorta via partial clamping. During inflow reduction and infra-coeliac cross-clamping, the coeliac trunk (CT) was divided and the proximal stent graft portion of the SPIDER-graft was deployed into the descending aorta via the CT ostium. Retrograde visceral and antegrade aorto-iliac blood flow was maintained via the iliac side branch. The visceral, renal, and iliac arteries were sequentially anastomosed, finally replacing the first iliac end to side anastomosis. Technical success, blood flow, periods of ischaemia, and peri-procedural complications were evaluated after intra-operative completion angiography and post-operative computed tomography angiography. RESULTS: Six animals underwent successful thoracic stent graft deployment and distal open reconstruction without peri-operative death. The median thoracic graft implantation time was 4.5 min, and the median ischaemia times before reperfusion were 10 min for the CT, 8 min for the superior mesenteric artery, 13 min for the right renal artery, and 22 min for the left renal artery. Angiography demonstrated appropriate graft implantation and blood flow measurements confirmed sufficient blood flow through all side branches. CONCLUSION: In this translational pig model, thoraco-abdominal hybrid repair using the novel SPIDER-graft was successful in avoiding thoracotomy and ECC. Technical feasibility and safety appear promising, but need to be reassessed in humans.
引用
- Debus ES, Kölbel T, Duprée A, et al. Feasibility Study of a Novel Thoraco-abdominal Aortic Hybrid Device (SPIDER-graft) in a Translational Pig Model. Eur J Vasc Endovasc Surg. 2017. PMID: 29290476. doi:10.1016/j.ejvs.2017.11.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。