弹力袜治疗慢性静脉疾病或血栓后综合征的依从性与并发症汇总分析
该汇总分析检索MEDLINE、EMBASE和CINAHL数据库,纳入58项临床研究(37项随机试验和21项前瞻性研究),共10245条肢体,评估慢性静脉疾病(CVD)或血栓后综合征(PTS)患者使用弹力袜的依从性和并发症。结果显示,8104例患者中5371例(66.2%)依从性良好,压力≤25 mmHg者依从性(77%)高于>25 mmHg者(65%),随机研究(74%)高于前瞻性观察研究(64%);43/62个队列未提及并发症,皮肤刺激是常见事件。
要点
- 弹力袜治疗CVD或PTS的总体良好依从率约66.2%。
- 压力≤25 mmHg者依从性(77%)高于>25 mmHg者(65%)。
- 多数研究未记录弹力袜并发症,皮肤刺激较常见。
核心结论
- 已发表试验中约三分之二患者对弹力袜治疗依从性良好,较高压力等级者依从性较低。
- 弹力袜并发症在许多研究中未被记录,未来需更多关注。
研究设计与样本
- 文献检索MEDLINE(via PubMed)、EMBASE(via OvidSP,1974年至今)和CINAHL(via EBSCOhost)。
- 纳入评估CVD(CEAP C2-C5)或PTS预防/治疗中使用弹力袜的研究。
- 最终纳入58项临床研究(37项随机试验和21项前瞻性研究),共10245条肢体。
主要发现
- 弹力袜压力范围15至40 mmHg(12项研究未说明),中位随访12个月(范围1-60个月)。
- 19个队列未评估依从性,另9个队列依从性描述不充分。
- 8104例患者中5371例(66.2%)报告依从性良好。
- 按研究规模加权平均依从性:压力≤25 mmHg为77%,>25 mmHg为65%;随机研究为74%,前瞻性观察研究为64%。
- 62个队列中43个未提及弹力袜并发症;考虑并发症时,皮肤刺激是常见事件。
关键数值与推荐
- 良好依从性定义为患者穿戴弹力袜时间>50%。
- 依从率按研究类型和压力程度进行比较。
临床怎么用
- 处方针织弹力袜时应考虑压力等级对依从性的影响,较高压力可能降低依从性。
- 临床随访中应主动评估和记录弹力袜相关并发症,如皮肤刺激。
局限性
- 19个队列未评估依从性,9个队列依从性描述不充分。
- 62个队列中43个未提及弹力袜并发症。
- 12项研究未说明弹力袜压力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Compression stockings are commonly prescribed for patients with a range of venous disorders, but are difficult to don and uncomfortable to wear. This study aimed to investigate compliance and complications of compression stockings in patients with chronic venous disease (CVD) and post-thrombotic syndrome (PTS). METHODS: A literature search of the following databases was carried out: MEDLINE (via PubMed), EMBASE (via OvidSP, 1974 to present), and CINAHL (via EBSCOhost). Studies evaluating the use of compression stockings in patients with CVD (CEAP C2-C5) or for the prevention or treatment of PTS were included. After scrutinising full text articles, compliance with compression and associated complications were assessed. Compliance rates were compared based on study type and degree of compression. Good compliance was defined as patients wearing compression stockings for >50% of the time. RESULTS: From an initial search result of 4303 articles, 58 clinical studies (37 randomised trials and 21 prospective studies) were selected. A total of 10,245 limbs were included, with compression ranging from 15 to 40 mmHg (not stated in 12 studies) and a median follow-up of 12 months (range 1-60 months). In 19 cohorts, compliance was not assessed and in a further nine, compliance was poorly specified. Overall, good compliance with compression was reported for 5371 out of 8104 (66.2%) patients. The mean compliance, weighted by study size, appeared to be greater for compression ≤25 mmHg (77%) versus > 25 mmHg (65%) and greater in the randomised studies (74%) than in prospective observational studies (64%). Complications of stockings were not mentioned in 43 out of 62 cohorts reviewed. Where complications were considered, skin irritation was a common event. CONCLUSIONS: In published trials, good compliance with compression is reported in around two thirds of patients, with inferior compliance in those given higher degrees of compression. Further studies are required to identify predictors of non-compliance, to help inform the clinical management of these patients. Complications of compression are not documented in many studies and should be given more consideration in the future.
引用
- Kankam HKN, Lim CS, Fiorentino F, et al. A Summation Analysis of Compliance and Complications of Compression Hosiery for Patients with Chronic Venous Disease or Post-thrombotic Syndrome. Eur J Vasc Endovasc Surg. 2018. PMID: 29329662. doi:10.1016/j.ejvs.2017.11.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。