文献速递静脉血栓栓塞慢性静脉疾病

神经肌肉电刺激减少腘静脉淤泥

Neuromuscular electrical stimulation reduces sludge in the popliteal vein.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2017-12-29

研究纳入25名健康志愿者,用B超记录腘静脉视频,比较腓总神经刺激器(CPNS)开启与关闭时静脉淤泥指数(VSI)。站立时VSI显著高于平卧,CPNS开启后所有体位和切面的VSI均显著降低(P < .0005),提示其可能通过减少静脉淤泥降低VTE风险。

要点

  • 站立位腘静脉VSI显著高于平卧位(P < .0005)。
  • CPNS开启后纵切和横切面VSI均显著降低(P < .0005)。
  • CPNS减少静脉淤泥的机制可能解释其降低VTE风险的潜在作用。

核心结论

  • CPNS设备可显著减少腘静脉内的静脉淤泥,无论受试者站立或平卧、超声探头纵切或横切。

研究设计与样本

  • 研究纳入25名健康志愿者,采用B型超声以22帧/秒记录右侧腘静脉视频,分别于CPNS关闭和开启时采集纵切与横切面图像。

主要发现

  • 站立位CPNS关闭时VSI显著高于平卧位:纵切面27.7(18.8-41.4) vs 11.7(5.5-17.5),横切面20.7(13.6-32.2) vs 11.4(6.3-15.9),P < .0005。
  • CPNS开启后所有展示的VSI均显著降低(P < .0005):纵切面2(1.1-3.2)和1.5(0.5-3.1),横切面1.1(0.6-2.7)和0.8(0.5-2.1)。

临床怎么用

  • CPNS可能通过减少静脉淤泥降低VTE风险,但红细胞聚集、静脉淤滞与VTE风险的关系需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The common peroneal nerve stimulator (CPNS) is a UK-approved device for reducing venous thromboembolism (VTE) risk. It resembles a wrist watch and is placed over the common peroneal nerve, discharging electricity at a rate of 1 impulse/s. It has been presumed that as blood flow slows, erythrocytes aggregate into ultrasound-detectable echogenic particles, described as venous sludge. The aim of the study was to determine whether the CPNS reduces venous sludge by using an ultrasound-derived gray-scale (0-255) venous sludge index (VSI). METHODS: Twenty-five healthy volunteers had their right popliteal vein video recorded using B-mode ultrasound at 22 frames/s in longitudinal and transverse views, standing and lying. This was performed first with the CPNS off and then with the CPNS on. The CPNS impulse intensity used was set from 1 to 7 for each individual, and the level was sufficient to cause an outward jerking movement of the foot. A single frame of the possible 154 frames, lasting 7 seconds, was selected using a random number generator for the image analysis. The "brightness" of the erythrocyte aggregates (pixels) within a circular sampling area was quantified using the VSI. The brighter the sample, the greater the sludge. RESULTS: Values are expressed as median (interquartile range). On standing with the device off, there was a significantly higher VSI (P < .0005) compared with lying (longitudinal view, 27.7 [18.8-41.4] vs 11.7 [5.5-17.5]; transverse view, 20.7 [13.6-32.2] vs 11.4 [6.3-15.9]). Activation of the CPNS significantly reduced all the VSI values (P < .0005) shown (longitudinal view, 2 [1.1-3.2] and 1.5 [0.5-3.1]; transverse view, 1.1 [0.6-2.7] and 0.8 [0.5-2.1]). CONCLUSIONS: The CPNS device significantly reduces venous sludge within the popliteal vein irrespective of whether the subject is standing or lying down or of the longitudinal or transverse position of the ultrasound transducer. The principal mode of action of the device in the claim that it may reduce venous thromboembolism risk may be through a reduction of venous sludge. However, the relationship between erythrocyte aggregation, venous stasis, and venous thromboembolism risk requires more investigation.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Lattimer CR, Azzam M, Papaconstandinou JA, et al. Neuromuscular electrical stimulation reduces sludge in the popliteal vein. J Vasc Surg Venous Lymphat Disord. 2017. PMID: 29292116. doi:10.1016/j.jvsv.2017.09.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。